![Miller Electric Maxstar 200 STR Owner'S Manual Download Page 23](http://html1.mh-extra.com/html/miller-electric/maxstar-200-str/maxstar-200-str_owners-manual_1796639023.webp)
OM-2233 Page 17
4-7. TIG Lift-Arc DCEN (Direct Current Electrode Negative) Connections
Ref. 802 888-A
Turn off power before mak-
ing connections.
1
Positive (+) Weld Output
Terminal
Connect work lead to positive weld
output terminal.
2
Negative (
−
) Weld Output
Terminal
Connect TIG torch to negative weld
output terminal.
3
Gas Cylinder
4
Cylinder Valve
Open valve slightly so gas flow
blows dirt from valve. Close valve.
5
Regulator/Flowmeter
6
Flow Adjust
Typical flow rate is 15 cubic feet per
hour (7.1 liters per minute).
Connect torch gas hose to regula-
tor/flowmeter.
7
Gas Valve
Valve controls gas preflow and
postflow. Open valve on torch just
before welding.
Tools Needed:
11/16 in, 1-1/8 in, (21 mm)
2
1
3
4
5
6
7