OM-193 267 Page 37
6-4. Removing Right Side Panel and Measuring Input Capacitor Voltage in
575 Volt Models
Turn Off welding power source, and
disconnect input power.
1
Right Side Panel
To remove panel, remove screws
securing panel to unit.
2
Interconnect Board PC2
3
Voltmeter
Measure the dc voltage across the
screw terminals on PC2 as shown
until voltage drops to near 0 (zero)
volts.
Proceed with job inside unit. Rein-
stall right side panel when finished.
Tools Needed:
5/16 in
Ref. ST-801 718 / Ref. ST-801 536-A
2
3
+ lead to lower right
terminal,
−
lead to
upper right terminal
1
!
Significant DC voltage can remain on capacitors af-
ter unit is Off. Always check the voltage as shown
to be sure the input capacitors have discharged be-
fore working on unit.
Summary of Contents for Invision 456MP
Page 4: ......
Page 14: ...OM 193 267 Page 10...
Page 30: ...OM 193 267 Page 26 4 8 How Manual Pulsed MIG Waveform Components Affect Arc and Burn Off Rate...
Page 45: ...OM 193 267 Page 41 193 264 A...
Page 46: ...OM 193 267 Page 42 Figure 7 2 Circuit Diagram For Welding Power Source 575 Volt Models...
Page 47: ...OM 193 267 Page 43 206 318 A...