OM-175 104 Page 11
5-2.
Optional Auxiliary Power Receptacles
Y
If unit does not have GFCI
receptacles, use GFCI-pro-
tected extension cord.
.
Auxiliary power decreases as
weld current increases.
Set Fine Adjust control R1 at
10 for full auxiliary power.
Combined output of all receptacles
limited to 8 kVA/kW rating of the
generator.
120 Volt Receptacle Option
1
120 V 15 A AC Receptacles
RC2 And RC3
RC2 and RC3 supply 60 Hz single-
phase power at weld/power speed.
Maximum output from RC2 or RC3
is 2.4 kVA/kW (CSA: 1.8 kVA/kW).
Circuit breaker protection is the
same as standard receptacles.
South African And Australian
Receptacle Options
2
240 V 16 A AC South African
Receptacles RC1, RC2, And
RC3
3
240 V 15 A AC Australian
Receptacles RC1, RC2, And
RC3
Receptacles supply 60 Hz single-
phase power at weld/power speed.
Maximum output from each recep-
tacle is 3.6 kVA/kW.
4
Circuit Breakers CB1, CB2,
CB3
CB1, CB2, and CB3 protect RC1,
RC2, and RC3 from overload. If a
circuit breaker opens, the recep-
tacle does not work. Press button
to reset breaker.
5
Circuit Breaker CB4
CB4 protects all the receptacles
from overload. If CB4 opens, none
of the receptacles work.
.
If a circuit breaker continues to
open, contact a Factory Au-
thorized Service Agent.
1
2
4
5
3
4
5
Ref. ST-172 786-B / Ref. ST-181 714