OM-496 Page 37
Return To Table Of Contents
7-4.
Remote Voltage/Amperage Control On CC/CV Models (Optional)
1
Remote 14 Receptacle RC14
Connect optional remote control to
RC14 (see Section 5-11).
0774 / Ref. 201 579 / 802 169-E
Example: Combination Remote Amperage Control (Stick)
Adjust Optional Remote Control
Set V/A
Adjust Switch
Set Range
Control Not
Used In Remote
Stick Mode
Set Remote
Process
Example: Combination Remote Amperage Control (TIG)
Adjust Optional Remote Control
Set V/A
Adjust Switch
Set Range
Set Control
Set Remote
Process
1
In Example:
Process = Stick (Using Remote On/Off)
Range = 110 to 315 A DC
Min = 110 A DC
Max = 315 A DC
Max (315 A DC)
Min (110 A DC)
In Example:
Process = TIG (Using Remote On/Off)
Range = 40 to 240 A DC
Percentage Of Range = 50%
Min = 40 A DC
Max = About 140 A DC (50% of 40 to 240)
Max (140 A DC)
Min (40 A DC)