www.GateOpenerSafety.com
2-5. Wire each of your
monitored devices
to the removable 4-pin connector as shown in Figure 2. If the
device is polarity sensitive, identify the correct common/ground wires. You do not need to use all 6
inputs.
2-6. Plug the
monitored device’s
connector into an appropriate input, as indicated in Figure 1.
2-7. To assign signal Output Types, select either “R” for Relay (10K or normally closed), or “P” for
Pulsed, as required by your gate operator. See Figure 3.
2-8. Each device input can have a different output assignment. Use the Input/Output Assignment DIP
switches to select A or B for each input that has a monitored device. See Figure 3.
Note: Input Channels 1 and 2 are hard-wired for Output A; switch positions 1 and 2 are ignored.
Figure 2
Figure 3
All 4-Wire
Devices
I
INPUT(+)
INPUT(-)
PWR(-)
PWR(+)
OUTPUT
POWER
10K
Sensing Edge
INPUT(+)
INPUT(-)
PWR(-)
PWR(+)
10K
EDGE
2-Wire Pulsed
Photo-Eye
INPUT(+)
INPUT(-)
PWR(-)
PWR(+)
PHOTO
EYE
All 3-Wire
Devices
A
INPUT(+)
INPUT(-)
PWR(-)
PWR(+)
OUTPUT
POWER