Millennia Media NSEQ page 6 of 9
NSEQ Rear Panel
1.
Inputs
—
In 1 (Left), In 2 (Right) Conventional 3-
pin female XLR input jacks for all balanced or
unbalanced line level signals.
2.
Outputs
—
Out 1 (Left), Out 2 (Right) Conventional
3-pin male XLR output jacks.
3.
Earth/Audio Ground Jumper
—
A barrier terminal
which ties earth ground to audio ground. If ground
"hum" loops are experienced when using the NSEQ-
4, removing this jumper may help. Using this
jumper, the integrity of the chassis/earth ground
connection is never compromised.
Do not defeat
the earth grounding pin on the AC plug.
4.
AC Voltage Mains Selection
—
The fuse block
contains two fuses; one fuse is in series with the hot
power line while the other fuse is in series with the
neutral power line. Both fuses must be installed.
To change the mains voltage selection, remove IEC power
connector and assure that the NSEQ-4 is not connected to
mains power. With a non-conductive tool, gently pry the fuse
block away from the power entry module. Slide out the
internal PC Board, turn it over, and reinsert the PCB so that
the desired AC mains voltage appears in the viewing window.
Double check that the fuses installed correspond to the AC
mains voltage range which appears in the viewing window.
Gently push the fuse block back until flush and snug.
Fuses
: For 100-120 VAC mains, use two 5 x 20 mm, 1A, slow
blow, 250 V, Littelfuse 218 or equiv. For 200-240 VAC mains,
use two 5 x 20 mm, 1A, slow blow, 250 V, Littelfuse 218 or
equiv.
5.
Power Entry
—
IEC Power Receptacle for use with
removable cords. Use only the power cord provided.
(Export units’ cords are
provided by the distributor.)