Millennia NSEQ-2 Owner'S Manual Download Page 6

Millennia Media NSEQ                                                                                                          page 6 of 9 

 

 

NSEQ  Rear Panel

1.

 

Inputs

 

 In 1 (Left), In 2 (Right) Conventional 3-

pin female XLR input jacks for all balanced or 
unbalanced line level signals. 

2.

 

Outputs

 

 Out 1 (Left), Out 2 (Right) Conventional 

3-pin male XLR output jacks.  

3.

 

Earth/Audio Ground Jumper 

 A barrier terminal 

which ties earth ground to audio ground. If ground 
"hum" loops are experienced when using the NSEQ-
4, removing this jumper may help. Using this 
jumper, the integrity of the chassis/earth ground 
connection is never compromised. 

Do not defeat 

the earth grounding pin on the AC plug.  

4.

 

AC Voltage Mains Selection 

 The fuse block 

contains two fuses; one fuse is in series with the hot 
power line while the other fuse is in series with the 
neutral power line. Both fuses must be installed.  

To change the mains voltage selection, remove IEC power 
connector and assure that the NSEQ-4 is not connected to 
mains power. With a non-conductive tool, gently pry the fuse 
block away from the power entry module. Slide out the 
internal PC Board, turn it over, and reinsert the PCB so that 
the desired AC mains voltage appears in the viewing window. 
Double check that the fuses installed correspond to the AC 
mains voltage range which appears in the viewing window. 
Gently push the fuse block back until flush and snug.  

Fuses

: For 100-120 VAC mains, use two 5 x 20 mm, 1A, slow 

blow, 250 V, Littelfuse 218 or equiv. For 200-240 VAC mains, 
use two 5 x 20 mm, 1A, slow blow, 250 V, Littelfuse 218 or 
equiv.  

5.

 

Power Entry

 

 IEC Power Receptacle for use with 

removable cords. Use only the power cord provided. 

(Export units’ cords are 

provided by the distributor.) 

Summary of Contents for NSEQ-2

Page 1: ...NSEQ Series Equalizers NSEQ 2 NSEQ 4 Owner s Manual...

Page 2: ...tch 5 7 Parametric Q Control 5 8 Master Equalizer In Out Select Switch 5 9 Twin Topology 5 10 Gain Range 5 11 Power Indicator 5 12 Power Switch 5 NSEQ 4 Front Panel 5 1 Band In Out Switch IN 5 2 Frequ...

Page 3: ...te ventilation on both sides of the NSEQ and avoid blocking the vents Power Sources Power Cord Protection The NSEQ Power Supply should be connected to a power source only of the type described in the...

Page 4: ...hat is property of Millennia and is intended solely for use by the purchasers of the equipment described in this manual Without express written permission Millennia prohibits the duplication of any po...

Page 5: ...he NSEQ 2 is powered up and active 12 Power Switch turns power on and off NSEQ 4 Front Panel 1 Band In Out Switch IN places its associated EQ band in circuit or out of circuit 2 Frequency Select Switc...

Page 6: ...in series with the neutral power line Both fuses must be installed To change the mains voltage selection remove IEC power connector and assure that the NSEQ 4 is not connected to mains power With a no...

Page 7: ...e switch selectable Hi Mid Sweep 250 Hz 2 5 kHz or 2 5 kHz 25 kHz 10X Range switch selectable High Range Switch Centers Peak Shelf Selectable 4 8 k 5 8 k 8 0 k 10 k 16 k 21 k THD Noise 20 Hz 30 kHz Al...

Page 8: ...Sweep 20 Hz 220 Hz or 200 Hz 2 2 kHz 10X Range switch selectable Hi Mid Sweep 250 Hz 2 5 kHz or 2 5 kHz 25 kHz 10X Range switch selectable High Range Switch Centers Peak Shelf Selectable 4 8 k 5 8 k...

Page 9: ...e of this product All warranties express and implied including the warranties of merchantability and fitness for a particular purpose are limited to the applicable warranty period set forth above Vacu...

Reviews: