LOC REAR PANEL  

 

(1) INPUTS: 

Bal Phono Input 1 / MM Conventional 3-pin 

female XLR input connectors for use with 

differential-balanced phono cartridges. Can also 

be used with certain line-level sources.  

 

Standard input load resistance is 47,000 ohms. 

This resistance can be changed by the user to 

facilitate different phono cartridge load 

requirements. See phono preamp PCB 

illustration on page 7.  

 

Standard input load capacitance is 470 pF. This 

capacitance can be changed by the user if 

necessary, but should not be lower than 270pF.  

XLR pin 2 is positive polarity. XLR pin 3 is 

negative polarity. Connector contacts are 

Neutrik gold plated. It is suggested that XLR 

cable connectors used with the LOCi employ 

identical plating.  

 

Bal Phono Input 2 /MC, Conventional 3-pin 

female XLR input connectors for use with all 

standard phono cartridges. Can also be used 

with certain line-level sources. Inputs 2 and 3 

connect to an input transformer, the Lundahl 

LL9226.  

 

Phono In 3/MC RCA input. To use the RCA input 

connections, select  “MC OUT” on the front panel  

Use your cartridge manufacturers recommended 

R/C loading. The cartridge loading can be 

modified by changing resistors and capacitors. 

See illustration on page 13.  

 

(2) PHONO PRE DIR OUT 

Buffered Direct output from the pre amp card.  

Post polarity and mono switching. This is the 

same signal fed into the compensation and filter 

circuits.  

 

(3) PHONO PRE TRIM OUT 

Adjustable, buffered signal derived from the 

Direct out. 

 

(4) UNBAL EQ OUT PRE TRIM 

Post filter and compensation circuit unbalanced 

signal. Available in both RCA and XLR 

connections. Output RCA connections are 

independent of input switching.  

 

(5) BAL EQ OUT POST TRIM 

Balanced output from the compensation and 

filter circuits. 

 

(6) EARTH/AUDIO GROUND JUMPER STRAP  

A barrier terminal which ties earth ground to 

audio ground. If ground “hum” loops are 

experienced when using the LOCi, removing this 

jumper may help. Using this jumper to lift 

ground, the integrity of the chassis/earth safety 

ground connection is never compromised.  

 

(7) AC VOLTAGE MAINS SELECTION  “100-

120” or “200-240” 

A power entry module with a removable fuse 

holder block. This fuse holder block is selectable 

for 100 - 120 Volt or 200 - 240 Volt worldwide 

mains powering. The fuse block contains two 

fuses - one fuse is in series with the hot power 

line while the other fuse is in series with the 

neutral power line. Both fuses must be installed. 

 

To change the mains voltage selection, remove 

IEC power connector and assure that the LOCi is 

not connected to mains power. With a non-

conductive tool, gently pry the fuse block away 

from the power entry module. Remove the two 

fuses and replace both with type as shown 

below.  

 

Slide out the internal PC Board, turn it over, and 

reinsert the PCB so that the desired AC mains 

voltage appears in the viewing window.  

 

Double check that the fuses installed correspond 

to the AC mains voltage range which appears in 

the viewing window. Gently push the fuse block 

back until flush and snug. 

 

FUSES: 

For 100-120 VAC mains, use two 5 x 20 mm, 

1A, slow blow, 250 V, Littelfuse 218 or equiv. 

 

For 200-240 VAC mains, use two 5 x 20 mm, 

1A, slow blow, 250 V, Littelfuse 218 or equiv. 

 

Use only the power cord provided with the LOCi 

unit or equivalent U/L approved type SV, SVT, 

SJ, or SJT AC power supply cord. Do not defeat 

the third pin earth ground. If ground lifting is 

desired, remove the Earth/Audio Ground Jumper 

Strap (topic #6, above). Export units are not 

supplied with a power cord 

Summary of Contents for LOCi

Page 1: ...llennia Media FPC 4600 Missouri Flat Road Placerville CA 95667 http www mil media com 530 647 0750 Fax 530 647 9921 Music Media Systems Owner s Manual Jf010715 LOCi Universal Playback Equalizer Phono...

Page 2: ...part without the written consent of Millennia Media FPC LOCi and Analog Legacy are trademarks of Millennia Media FPC with all rights reserved All other trademarks herein are property of their respect...

Page 3: ...as a record of your purchase to aid positive identification in the event of loss INTRODUCTION The LOCi Analog Legacy is a hand crafted collection of Millennia s essential preamplifier and equalizer ci...

Page 4: ...RCA and XLR connections Output RCA connections are independent of input switching 5 BAL EQ OUT POST TRIM Balanced output from the compensation and filter circuits 6 EARTH AUDIO GROUND JUMPER STRAP A b...

Page 5: ...switches A Green and B Amber determine the gain range of the rotary switch When the pushbutton switches are not depressed and non illuminated the phono preamplifier gain is as printed on the front pan...

Page 6: ...WITCH Pushbutton switch which selects LF and HF filter curve shape When switch is depressed and LED is illuminated EQ is shelving at 6 dB per octave When switch is not depressed EQ is peaking with a f...

Page 7: ...ns Standard input load resistance is 47 000 ohms This can be changed by the user to facilitate different phono cartridge load requirements Standard input load capacitance is 470 pF This capacitance ca...

Page 8: ...ging in different value capacitors into the filter boards that are connected to the respective selection knob on the front panel To change the value unplug the unit from power remove the top panel 12...

Page 9: ...Placerville CA 95667 http www mil media com 530 647 0750 Fax 530 647 9921 Top view high comp C8 value s Attenuation at 10KHz 5600 pF 17 dB 6200 pF 18 dB 6800 pF 19 dB 8200 pF 20 dB 9200 pF 21 dB 0 01...

Page 10: ...xperimentation and other sources for records made generally between 1925 and 1955 The audio engineer should use these numbers as a guide only Ultimately use your ears as the final reference for correc...

Page 11: ...2 or 16 Cetra 400 11 Coliseum 400 12 Columbia 1925 200 7 Columbia 1926 250 5 Columbia 1938 most 300 16 Columbia various COL 16 Columbia European 300 5 Concert Hall 400 12 Contemporary 400 11 Cook Labo...

Page 12: ...0 HMV 1946 1954 500 or 800 16 HMV American 400 12 Handel Society 750 16 or 17 Haydn Society 750 16 or 17 Harmony Acoustics thru 8 29 300 16 Hit of the Week 500 5 Kapp 700 16 Kendall 629 16 King 500 16...

Page 13: ...athe inconsistent adjust as required Period 500 16 Polydor 300 8 5 Philharmonia 400 12 Polymusic 500 16 Ploymusic binaural inside band 500 0 RCA Victor early acoustics 71 29 RPM 0 0 RCA Victor later a...

Page 14: ...Vocalion electricals 300 0 VOX 500 or 750 16 War Department 12 Special Services 700 5 Western Electric early transcriptions 300 0 Westminster pre 1956 500 or 750 16 Westminster AES printed on jacket...

Page 15: ...Unbal Out 73dB MC To Post EQ Trim Out 88dB Input Impedance User selectable resistor capacitor Factory Stock 47 5k ohms 270 pF Output Impedance 49 9 ohms unbalanced Noise Better than 127 dB EIN flat al...

Page 16: ...med by anyone other than Millennia Media or its authorized agent LIMITS AND EXCLUSIONS There are no express warranties except as listed above Millennia Media shall not be liable for special subsequent...

Reviews: