background image

LOOX EYE-CONTROL FOR MACROPATH 

MM171-001

–Operator Manual 

 
 

33 

 

6  MAINTENANCE 

 

 
 

 

 

LOOX Eye-Control for MacroPATH does not require any year maintenance. In case of trouble 
contact 

your 

local 

distributor 

or 

Milestone 

offices 

directly: 

[email protected]

.

 

Summary of Contents for 370635

Page 1: ...OperatorManual MM171 MILESTONE H E L P I N G P A T I E N T S ...

Page 2: ......

Page 3: ...read this operator manual carefully and always keep it within reach for convenient and quick referencing For any clarification or request for assistance please contact our representative in your country Or contact Milestone s r l Via Fatebenefratelli 1 5 24010 Sorisole BG Italy Tel 39 035 412 8264 Fax 39 035 575498 web site www milestonemed com e mail marketing milestonemedsrl com Read this manual...

Page 4: ...anufacturer 11 2 INSTALLATION 12 2 1 Unpacking and check list 12 2 2 Placement 13 2 3 Software installation 14 2 4 License activation 16 2 5 Create a new user s profile 17 2 5 1 How does the calibration work 18 3 SETTINGS 19 3 1 Game and experiences 20 3 2 Interactions 21 3 2 1 Power 21 3 2 2 Touchpad 23 3 2 3 Mouse 24 3 2 4 Windows 25 3 2 5 About 26 3 3 Display setup 27 3 4 Gaze trace 28 4 USE of...

Page 5: ... equipment and Telecommunications Terminal Equipment Directive 2004 108 EC EMC Electromagnetic Compatibility Directive 2006 95 EC LVD Low Voltage Directive LOOX Eye Control for MacroPATH complies with the following standards IEC EN 62471 2008 Photo Biological Safety of Lamps and Lamp Systems EMC Emission EN 61000 6 3 2007 Generic Emission standard for residential commercial and light industry envi...

Page 6: ...rom keyboard and touchscreen to hands free technique transforming the way to interact with device data and users The solution relates to a method based on an eye tracking application characterized by a perceptual interface designed to facilitate the display manipulation analysis and sharing of medical images which replaces keyboard and mouse with most intuitive and efficient visual control Any oth...

Page 7: ...cifications OS Windows 10 Professional Enterprise 64 bit only CPU minimum requirements 2 0GHz Intel i5 or i7 RAM minimum requirements 8GB USB Connectivity USB 2 0 integrated cord USB 2 0 BC 1 2 1 3 3 Biometrix Safety The Windows Hello biometric functionality relies on images provided by sensor to work with Microsoft face recognition algorithms Built into Windows 10 these algorithms determine the i...

Page 8: ...f the equipment is not working properly contact your supplier or the manufacturer Do not remove the instrument optional parts panels or cover Only authorized and qualified SERVICE personnel may repair the instrument and access the instrument s internal components It is important that normal standards for safety and good laboratory practices are applied Always use common sense and the best known pr...

Page 9: ...es of an eye tracker It is estimated that about 3 5 of people with epilepsy have this type of photosensitive epilepsy Many people with photosensitive epilepsy experience an aura or feel odd sensations before the seizure occurs If you feel odd during use move your eyes away from the eye tracker INFRARED WARNING When activated LOOX Eye Control emits pulsed infrared IR light Certain medical devices a...

Page 10: ...pment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into a wall outlet on a circuit different from that to which the receiver is connected Consult the dealer or experienced radio TV technician for assistance 1 5 ...

Page 11: ...on manual must be supplemented by appropriate instructions to ensure compliance to such requirements 1 7 Return for repair to manufacturer This instrument is not an in vitro medical diagnostic device and it is usually installed in a laboratory where samples and other biological tissues are present For your safety it must therefore be cleaned and disinfected before use and gloves must be worn when ...

Page 12: ...ON 2 1 Unpacking and check list DESCRIPTION QUANTITY IMAGE Mounting brackets 2 Eye tracker with USB cable 1 USB key with Serial Number including Milestone license file Tobii software Operator manual in electronic format 1 The images shown are for illustrative purposes only ...

Page 13: ...ent Clean with alcohol base reagent the center of the PC under the video where the bracket will be attached Peel off the adhesive and apply the mounting bracket on the center of PC Put the Eye tracker on the magnetic mounting bracket Plug Eye Tracker into a USB port on PC ...

Page 14: ...nsert the USB key on PC and open LOOX folder Run as administrator the file Tobii_Eye_Tracking_Core_v2 16 5 156_X86 exe In the software installer tick Agree and then select Next Wait for installing this should take just a couple of minutes Once the installation is complete select Continue ...

Page 15: ...lect Next Make sure your Eye Tracker is positioned at the bottom center of your monitor and align the lines that are on display with your mouse to the lines present on the LOOX Eye Control device Select Done LOOX Eye Control icon will be displayed on the tool bar ...

Page 16: ...e folder Milestone License and License File The showed Serial Number is only an example Copy the file CAVS_MWI_DLL lic in the MacroPATH5 folder C Program files x86 Milestone srl MacroPath5 LOOX Eye Control device works only with its license the license is not bound to the PC but to the LOOX Eye Control device The licence does not expire ...

Page 17: ...OL FOR MACROPATH MM171 001 Operator Manual 17 2 5 Create a new user s profile Make sure the Eye Tracker can see your eyes Follow the on screen instructions to calibrate your eye tracker Type your name and select Save ...

Page 18: ...nt on a screen When you calibrate we measure characteristics and calculate the personal differences such as where your pupil is located in relation to your cornea and fovea at the back of your eye We do this to give you the best accuracy possible Therefore it is not required to re calibrate on a regular basis unless you have changed your light environment We do however recommend you to do one cali...

Page 19: ...al 19 3 SETTINGS After software installation and licensing LOOX Eye Control icon will be displayed on the tool bar Double click on it then to activate LOOX Eye Control select ON To create a new user s profile refer to the procedure described in chapter 2 4 ...

Page 20: ...OR MACROPATH MM171 001 Operator Manual 20 3 1 Game and experiences This section refers to a different use of the tracker according to the possibilities offered by the manufacturer It is not linked to the use of MacroPATH ...

Page 21: ...e or deactivate all the functions of Interactions menu POWER TOUCHPAD MOUSE WINDOWS ABOUT Refer to the below chapters 3 2 1 Power Power Available in Windows 10 With the Eye Tracker active the computer can automatically sense if you are present in front of the screen or not If the eye tracker can detect your eyes the screen will stay lit ...

Page 22: ... will not detect your eyes and it will dim your screen after a pre set time We advise to set Dim brightness OFF If it is set ON you can specify the Time before dimming Stay Awake Your computer will stay awake while you are in front of your eye tracker We advise to set Stay Awake OFF Turn on screen Your screen will turn on as soon as the eye tracker has detected your presence We advise to set Turn ...

Page 23: ...ROL FOR MACROPATH MM171 001 Operator Manual 23 3 2 2 Touchpad This section refers to a different use of the tracker according to the possibilities offered by the manufacturer It is not linked to the use of MacroPATH ...

Page 24: ...arp on mouse move We advise to set this option OFF Just slightly move the mouse to trigger the mouse pointer to appear where you look The mouse cursor will appear where you look on the screen just by starting to move the mouse You have the option to only warp when moving pointer towards where you look Inactive zone can be set to 1cm and up to 10cm Mouse warp on key We advise to set this option No ...

Page 25: ...r Win key and then tap the Tab key 2 Keep the Alt or Win key pressed 3 Look at the application you want to go to 4 Release the Alt or Win key 5 You will now go to the application you looked at Task view We advise to set this option OFF 1 Open Windows Task View by pressing and holding the Windows key then tapping the tab key 2 In Task View look at an app to highlight it Since the Windows 10 Version...

Page 26: ...nap assist We advise to set this option OFF 1 Look at the menu item you want The menu item will highlight 2 Press the Enter key to confirm You will now execute the chosen menu item 3 2 5 About It refers to TOBII company information which is the manufacturer of the device ...

Page 27: ...LOOX EYE CONTROL FOR MACROPATH MM171 001 Operator Manual 27 3 3 Display setup It refers to software installation for more details see chapter 2 3 ...

Page 28: ... 28 3 4 Gaze trace It is used to allow the user a better user experience by tracking what is pointed with the eyes with a visual feedback We advise to set this option ON at least to start familiarizing yourself with the instrument then you can deactivate it ...

Page 29: ... ICON showed below Select the profile To create a new user profile refer to chapter 2 4 Run MacroPATH We suggest to create users also in MacroPATH software and login to MacroPATH with the same user profile selected in LOOX Eye Control software Refer to MM161 MacroPATH and MacroPATH Basic QX Series Operator Manual for how to create a user Select Settings ...

Page 30: ...he icon to select and when it is activated Default value is 600 milliseconds suggested It can be modified and insert values between 0 and 2500 milliseconds Save close MacroPATH and restart the program Run MacroPATH The zoom bar will be modified according to the below picture Now it is possible to use the following functions with LOOX Eye Control LIVE SAVE IMAGE REC VIDEO REC AUDIO ZOOM ZOOM 600 ...

Page 31: ...trol log files will be saved in C ProgramData Milestone srl LOOX APPDATA If Alternative Zoom Bar is not selected it is not possible to use LOOX Eye Control with standard zoom bar Refer to the MM161 MacroPATH e MacroPATH BASIC QX Series Operator Manual to work with MacroPATH ...

Page 32: ...ard EN 149 Grade FFP3D and Directive 89 686 EEC It is recommended to use alcohol based rapid disinfectant for non invasive medical products and other surfaces on basis of alcohol DISCONNECT THE PLUG FROM THE SOCKET BEFORE STARTING THE CLEANING UP PROCEDURE Cleaning up steps 1 Prepare agent as per the manufacturer s instructions or hospital protocol 2 Wipe the instrument with a clean cloth that has...

Page 33: ...TH MM171 001 Operator Manual 33 6 MAINTENANCE LOOX Eye Control for MacroPATH does not require any year maintenance In case of trouble contact your local distributor or Milestone offices directly customersupport milestonemedsrl com ...

Page 34: ...t be detected If you have only undergone surgery on one of your eyes that left scars and makes the reflection distorted then you have the option to exclusively track the other eye This can be selected in your profile settings Have in mind though that every case is different Recommendations There are certain types of glasses that could affect the accuracy and the precision of the gaze estimation Bi...

Page 35: ...might limit the amount of power given to each USB device 2 In case the LOOX Eye Control is not recognized check Open Device Manager and expand Universal Serial Bus devices The driver for your Eye Tracker is named EyeChip If this is listed your PC can detect the tracker so double click to open Are there any error messages for the driver If so make sure to update Windows so you have all the latest u...

Page 36: ......

Page 37: ......

Page 38: ......

Page 39: ......

Page 40: ...marketing milestonemedsrl com www milestonemed com Via Fatebenefratelli 1 5 24010 Sorisole BG Italy Tel 39 035 4128264 Fax 39 035 575498 Milestone Srl ...

Reviews: