background image

4

1. Product Introduction

1.1 Overview

EM310-UDL is a LoRaWAN

®

ultrasonic distance/level sensor mainly used for detection of waste

bin and other container’s level. With a compact size and wide measure range, EM310-UDL can
be installed to any types of waste bins or containers to monitor solid or liquid level. Besides,
EM310-UDL equips with 3-axis accelerometer to detect the status of container cover. It is
equipped with NFC (Near Field Communication) and can easily be configured by a smartphone.

Sensor data are transmitted in real-time using standard LoRaWAN

®

protocol. LoRaWAN

®

enables encrypted radio transmissions over long distance while consuming very little power.
The user can obtain sensor data and view the trend of data change through Milesight IoT Cloud
or through the user's own Network Server.

1.2 Features

3 to 450 cm wide measuring range with short bind zone

Support temperature compensation for high accuracy

Up to 15 km communication range

Easy configuration via NFC

Standard LoRaWAN

®

support

Milesight IoT Cloud compliant

Low power consumption with 7000mAh replaceable battery

2. Hardware Introduction

2.1 Packing List

1 × EM310-UDL

Device

2 × Mounting

Kits

2 × Screw

Caps

1 ×

Warranty Card

1 ×

Quick Guide

If any of the above items is missing or damaged, please contact your sales representative.

Summary of Contents for EM310-UDL

Page 1: ...Milesight IoT Ultrasonic Distance Sensor EM310 UDL User Guide...

Page 2: ...ever be subjected to shocks or impacts Declaration of Conformity EM310 UDL is in conformity with the essential requirements and other relevant provisions of the CE FCC and RoHS Copyright 2011 2021 Mil...

Page 3: ...ide 5 3 1 NFC Configuration 5 3 2 LoRaWAN Settings 6 3 3 Basic Settings 9 3 4 Advanced Settings 10 3 4 1 Calibration Settings 10 3 4 2 Threshold Settings 10 3 5 Maintenance 11 3 5 1 Upgrade 11 3 5 2 B...

Page 4: ...LoRaWAN protocol LoRaWAN enables encrypted radio transmissions over long distance while consuming very little power The user can obtain sensor data and view the trend of data change through Milesight...

Page 5: ...seconds Off On Switch Off Press and hold the button for more than 3 seconds On Off Reset Press and hold the button for more than 10 seconds Quickly Blinks Check On Off Status Quickly press the power b...

Page 6: ...utton to write all your settings to the device Note 1 Ensure the location of smartphone NFC area and it s recommended to take off phone case 2 If the smartphone fails to read write configurations via...

Page 7: ...for ABP mode default is 5572404C696E6B4C6F52613230313823 Spread Factor If ADR is disabled the device will send data via this spread factor Confirmed Mode If the device does not receive ACK packet fro...

Page 8: ...ngs of ToolBox App to select supported frequency and select channels to send uplinks Make sure the channels match the LoRaWAN gateway If frequency is one of CN470 AU915 US915 you can enter the index o...

Page 9: ...the reporting interval etc Parameters Description Reporting Interval Reporting interval of transmitting data to network server Default 10 mins Range 1 1080 mins Tilt Distance Switch When detected the...

Page 10: ...can define either outlier range or value When the device distance value exceeds the outlier range or value comparing to last value the device will measure the distance again 3 4 2 Threshold Settings...

Page 11: ...version ToolBox supports the upgrade feature 3 5 2 Backup EM310 UDL support configuration backup for easy and quick device configuration in bulk Backup is allowed only for devices with the same model...

Page 12: ...dit the configurations 3 5 3 Reset to Factory Default Please select one of following methods to reset device Via Hardware Hold on power button internal for more than 10s Via ToolBox App Go to Device M...

Page 13: ...nternal obstructions that block the ultrasonic signal If the device has to install on the side wall please ensure the ultrasonic sensor direction point away from the wall 5 Milesight IoT Cloud Managem...

Page 14: ...lesight IoT Cloud you can check the data via webpage or mobile App and create dashboard for it 6 Device Payload All data are based on following format HEX Channel1 Type1 Data1 Channel2 Type2 Data2 Cha...

Page 15: ...3b31056670013 ff090100 ff0a0100 ff0f00 Channel Type Value Channel Type Value ff 0b Power On ff Reserved ff 01 Protocol Version 01 V1 Channel Type Value Channel Type Value ff 16 Device SN 6713b31056 67...

Page 16: ...pplication port is 85 by default Example Set reporting interval as 20 minutes END Channel Type Value 04 00 Device Position 00 Normal Channel Type Description ff 03 Set Reporting Interval 2 Bytes unit...