Miles Industries Valor RBWSK Installation Manual Download Page 3

3

13.  Make the snap connection, load 4 new 

alcaline

 AA 

battery into holder (included with fireplace) then 

feed back into junction box assembly.

DO NOT put batteries in the receiver, only in the 

battery holder by the wall switch.

14.  Test the operation of the wall switch.

Wall Switch Operation

The Wall Switch can be used to control the fireplace. 

You can turn the pilot on or off and you can increase or 

decrease the flame height. 
Note that the thermostat and programming functions 

are not available with the wall switch.

9.  Locate and secure magnet plate using 2 ‘long’ 

screws provided.

10.  Place and secure cover plate to box using 4 screws 

provided.

11.  Feed cable tie through the 2 side slots of battery 

cover assembly.

12.  Position battery holder to rear face and secure 

together with cable tie. Note the clearance required 

for battery snap connection.

Snap connector

Cable tie

Side slot

Rear view

Front view

•  Press ON-OFF button once to light 

pilot. Press again to shut of pilot.

•  Press and hold large flame     

button to gradually increase 

flame height.

•  Press and hold small flame    button 

to gradually decrease 

flame height.

To turn appliance ON and OFF

To adjust flame height

Summary of Contents for Valor RBWSK

Page 1: ...d heater models If this kit is to be used on a Valor fireplace installed outdoor the position and mounting of this assembly must be in a sheltered place protected from the elements dry location The Remote Battery and Wall Switch Kit RBWSK makes the fireplace batteries more accessible while consolidating their location with the wall switch The batteries of the RBWSK are connected to the fireplace r...

Page 2: ...Installation Locate the receiver in the appliance s case Refer to the appliance s installation manual if necessary 1 Pull out the receiver from its location to connect the battery holder and wall switch 2 Feed the white connector end of the harness assembly through side holes in fireplace liner body to receiver Ensure sufficient harness length to allow for removal of receiver Coil up any extra har...

Page 3: ...e not available with the wall switch 9 Locate and secure magnet plate using 2 long screws provided 10 Place and secure cover plate to box using 4 screws provided 11 Feed cable tie through the 2 side slots of battery cover assembly 12 Position battery holder to rear face and secure together with cable tie Note the clearance required for battery snap connection Snap connector Cable tie Side slot Rea...

Page 4: ...4 Wiring Diagram Wall Switch Kit GV60 Wiring Diagram Remote Battery Holder 4 AA Batteries 5 pin connector 9 Volt connector ...

Page 5: ...4005523 7 Junction box 4005527 8 Cover plate screws 4005526 9 Cable tie 4005524 1 2 3 9 6 7 8 5 4 Designed and Manufactured by for Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver B C CANADA V7H 3B1 Tel 604 984 3496 Fax 604 984 0246 www valorfireplaces com Because our policy is one of constant development and improvement details may vary slightly from those given in this publication...

Page 6: ...tion des modèles mentionnés ci haut Si vous utilisez ce kit sur un foyer Valor installé à l extérieur la position et le montage du kit doit être dans un endroit à l épreuve des intempéries endroit sec Le kit Porte piles et Interrupteur mural RBWSK facilite l accès aux piles du foyer en les plaçant à côté de l interrupteur mural Les piles du RBWSK sont branchées au récepteur du foyer et en conséque...

Page 7: ...on de l appareil si nécessaire 1 Tirez le récepteur hors position pour le branchez au porte piles et interrupteur mural selon les directives suivantes 2 Faites passer la fiche de connexion blanche du harnais de connexion par un des trous de côté de la boîte de foyer jusqu au récepteur Assurez vous que le fil est assez long pour manipuler le récepteur une fois branché Conservez toute longueur addit...

Page 8: ... à aimants à côté de l interrupteur et fixez la à la boîte de raccordement à l aide de 2 longues vis fournies 10 Placez la plaque de la boîte de raccordement et fixez la à la boîte à l aide de 4 vis fournies 11 Insérez l attache autobloquante dans les deux fentes du couvercle du compartiment à piles 12 Placez le porte piles contre l arrière du couvercle et fixez le avec l attache autobloquante Lai...

Page 9: ... à 5 broches Connecteur 9 volt Commutateur de réinitialisation Récepteur Antenne Câble de l électrode Bloc interrupteur Câble de 8 fils Veilleuse Soupape combinée Étincelle Étincelle Thermocourant Bloc interrupteur Interrupteur marche arrêt Bouton principal de la soupape Bouton manuel Terminal rouge Rouge Jaune ...

Page 10: ...de raccordement 4005527 8 Plaque boîte de raccordement et 4 vis 4005526 9 Attache autobloquante 4005524 Conçue et fabriquée par pour Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC CANADA V7H 3B1 Tél 604 984 3496 Téléc 604 984 0246 www fr valorfireplaces com Notre politique en est une de développements et améliorations constants certains détails peuvent varier de ceux donnés dan...

Reviews: