The recorder offers an option of printing the recorded readings and the last 

registered reading sample in form of a short report. It also offers an option 

of printing a report of recordings stored in the memory of the device. 

To print the short report, press the              button.

To print a report from the earlier recordings, press the             button and 

select the number of the earlier recording with the             button. 

The following information will be then displayed on the LED panel: 

START

STOP

START

STOP

 

--------------------------------
--------------------------------
--------------------------------

MIXTER TRANS TRANSPORT COMPANY 

REPORT FROM DELIVERY CONDITIONS

DD.MM.YY HH:MM |  T ‘C  H %   **
--------------------------------
01.01.09 12:46 |  25.8   32   +-

     

Loggicar E v001

     

www.mikster.com

OPERATING MANUAL: LOGGICAR-E, VERSION 1.2

Summary of Contents for Loggicar-E

Page 1: ... Operating Manualversion 1 2 VEHICLE TEMPERATURE AND HUMIDITY RECORDER ...

Page 2: ...MIKSTER Sp z o o 41 250 Czeladź ul Wojkowicka 21 tel 48 32 763 77 77 fax 48 32 763 75 94 www mikster pl mikster mikster pl M I K S T E R ...

Page 3: ...f Contents PURPOSE 2 OPERATING PANEL 3 RECORDING THE READINGS 3 PRINTING 5 SERVICE FUNCTIONS AVAILABLE TO THE USER 8 DISPLAY MODE 9 SETTING THE PRINTOUT HEADINGS 10 SERVICE FUNCTIONS 11 OPERATING MANUAL LOGGICAR E VERSION 1 2 ...

Page 4: ...ation condition and satisfying the HACCP The recorder conforms to the requirements of the PN EN 12830 Standard and the WE89 3EWG Directive Loggicar e ensures a constant supervision of the temperature regardless of the efficiency of the aggregate TECHNICAL SPECIFICATION Number of samples per registration 500 Number of registrations 20 Paper width 57 mm Print type thermal 2 measuring inputs for CLIP...

Page 5: ...is displayed cyclically on the LED panel current time temperature from the first SP probe temperature or humidity from the second probe optional RECORDING THE READINGS The readings recording process begins after pressing the The following information will be displayed on the LED panel START STOP START STOP START STOP OPERATING MANUAL LOGGICAR E VERSION 1 2 ...

Page 6: ...g information will be then displayed on the LED panel Examples of the recording configurations Recording frequency Recording time 1min 8 hours 20 min 5min 1 day 17 hours 40 min 10min 3 days 11 hours 15min 5 days 5 hours 30min 10 days 10 hours 60min 20 days 20 hours 120min 41 days 16 hours 240min 83 days 8 hours START STOP START STOP OPERATING MANUAL LOGGICAR E VERSION 1 2 ...

Page 7: ... device To print the short report press the button To print a report from the earlier recordings press the button and select the number of the earlier recording with the button The following information will be then displayed on the LED panel START STOP START STOP MIXTER TRANS TRANSPORT COMPANY REPORT FROM DELIVERY CONDITIONS DD MM YY HH MM T C H 01 01 09 12 46 25 8 32 Loggicar E v001 www mikster ...

Page 8: ...e 15 05 09 13 12 Unloading time 15 05 09 13 20 Alarm 1 max 25 0 C Alarm 1 min 20 0 C Alarm 2 max 35 0 Alarm 2 min 25 0 DD MM YY HH MM T C H 15 05 09 13 12 23 5 25 15 05 09 13 13 23 6 25 15 05 09 13 14 24 1 90 15 05 09 13 15 25 1 96 15 05 09 13 16 26 0 97 15 05 09 13 17 26 5 95 15 05 09 13 18 26 8 26 15 05 09 13 19 27 2 24 15 05 09 13 20 27 2 20 Loggicar E v001 www mikster com OPERATING MANUAL LOGG...

Page 9: ...ory of the device select the registration No 21 REPORT FROM DELIVERY CONDITIONS RECORDINGS LIST No Loading Unloading DD MM YY HH MM DD MM YY HH MM 01 08 05 09 15 49 11 05 09 07 49 02 11 05 09 09 28 11 05 09 11 16 Loggicar E v001 www mikster com OPERATING MANUAL LOGGICAR E VERSION 1 2 ...

Page 10: ... chapter DISPLAY MODES F6 Setting the temperature units 0 Fahrenheit 1 Celsius F7 Alarm zone exceeding the minimum temperature of the first probe range 50 120 F8 Alarm zone exceeding the maximum temperature of the first probe range 50 120 F9 Alarm zone exceeding the minimum temperature or humidity of the second probe range 50 120 F10 Alarm zone exceeding the maximum temperature or humidity of the ...

Page 11: ...sible to set the cyclic display of time and readings or the constant display of one selected reading Available settings of the F5 cell are presented in table below Number set in the F5 cell Displayed data 1 current time recording number temperature reading from the first probe temperature humidity reading from the second probe this step is omitted for devices equipped with only one probe 2 tempera...

Page 12: ...sity to select all 32 digits Sign table Number of the particular sign and its equivalent appearing on the printout H4 set into 0 or 1 H4 set into 2 1 Space 2 A 3 B 4 C 5 D 6 E 7 F 8 G 9 H 10 I 11 J 12 K 13 L 14 M 15 N 16 O 17 P 18 Q 19 R 20 S 21 T 22 U 23 V 24 W 25 X 26 Y 27 Z 28 0 29 1 30 2 31 3 32 4 33 5 34 6 35 7 36 8 37 9 1 Space 2 A 3 Б 4 В 5 Г 6 Д 7 Е 8 Ё 9 Ж 10 З 11 И 12 Й 13 К 14 Л 15 М 16...

Page 13: ...tions menu Service functions table Function number Description H1 Selecting the configuration of the recorder H1 1 Single probe mode probe located at the first entry of the recorder H1 2 Two probe mode H1 3 Temperature humidity mode H2 Setting the offset for the first temperature H3 Setting the offset for the second temperature humidity range 20 20 H4 Setting the language of the printed reports 0 ...

Page 14: ...12 NOTES OPERATING MANUAL LOGGICAR E VERSION 1 2 ...

Page 15: ...13 NOTES OPERATING MANUAL LOGGICAR E VERSION 1 2 ...

Page 16: ... mikster pl The device shall be used in accordance to the operating manual and with the purpose for which it was developed The guarantee becomes void in the following cases In case of breaking the seal In case of mechanical damage In case of damage caused by the improper use of the device In case of introducing changes to the guarantee card with an exception of changes intro duced by the manufactu...

Reviews: