MC136x/MC137x GenICam Reference Manual
17
RecordTrailer
This feature defines the number of frames to record after a record stop trigger is detected. The
default value is 0.
Feature name
RecordTrailer
Access
Read/Write
Interface
IInteger
Unit
number of picture
Range
0… (RecordMaxFramesPerSequence-1)
Response
e.g. 0
Invalidation
Precondition
CameraState = Idle, RecordMaxFramesPerSequence
Note
RecordMaxFrames
This feature indicates the maximal number of frames that can be recorded in sum of all defined
sequences.
Feature name
RecordMaxFrames
Access
Read only
Interface
IInteger
Unit
number of picture
Range
--
Response
e.g. 3274
Note
RecordNumberOfFrames
This feature indicates the number of recorded frames in sum off all defined sequences.
Feature name
RecordNumerOfFrames
Access
Read only
Interface
IInteger
Unit
number of picture
Range
--
Response
e.g. 3274
Note