background image

netPower 16P

netPower 16P (CRS318-16P-2S+OUT) 

The netPower is a weatherproof switch with the capability of delivering PoE to your connected devices.

Safety Warnings

Before you work on any equipment, be aware of the hazards involved with electrical circuitry, and be familiar with standard practices for preventing 

accidents.

Ultimate disposal of this product should be handled according to all national laws and regulations.

The Installation of the equipment must comply with local and national electrical codes.

This product is intended to be mounted outdoors on a pole. Please read the mounting instructions carefully before beginning installation. Failure to use the 

correct hardware and configuration or to follow the correct procedures could result in a hazardous situation for people and damage to the system.

Use only the power supply and accessories approved by the manufacturer, and which can be found in the original packaging of this product.

Read the installation instructions before connecting the system to the power source.

We cannot guarantee that no accidents or damage will occur due to the improper use of the device. Please use this product with care and operate at your 

own risk!

In the case of device failure, please disconnect it from power. The fastest way to do so is by unplugging the power plug from the power outlet.

It is the customer's responsibility to follow local country regulations, including operation within legal frequency channels, output power, cabling 

requirements, and Dynamic Frequency Selection (DFS) requirements. All Mikrotik devices must be professionally installed.

Quickstart

Please follow these quick steps to set up your device:

Open the bottom lid (see "

");

Bottom Lid

Connect all served devices to Ethernet ports;

Connect the device to the power source (see "

");

Powering

Once connected to the same network, open 

 in your web browser to start configuration, user name: a

 and there is no 

https://192.168.88.1

dmin

password by default;

Once connected configure the device, so it has an active Internet connection 

;

https://mt.lv/configuration

Upgrade the RouterOS software to the latest version 

;

https://mt.lv/upgrade

Set up your router password in the bottom field of the QuickSet menu, to the right and repeat it, it will be used to login next time.

Expansion slots and ports

Summary of Contents for CRS318-16P-2S+OUT

Page 1: ... guarantee that no accidents or damage will occur due to the improper use of the device Please use this product with care and operate at your own risk In the case of device failure please disconnect it from power The fastest way to do so is by unplugging the power plug from the power outlet It is the customer s responsibility to follow local country regulations including operation within legal fre...

Page 2: ...S includes many configuration options in addition to what is described in this document We suggest starting here to get yourself accustomed to the possibilities https mt lv help For recovery purposes it is possible to boot the device for reinstallation see section Buttons and Jumpers Powering The device accepts power in the two ways following ways Direct input power jack 1 5 5 mm outside and 2 mm ...

Page 3: ...he power cord into a power outlet Bottom Lid Bottom lid is secured in place with the captive screw it can be unscrewed by hand but do not remove the screw completely Pull the cover towards Lift to access Ethernet ports Mounting The device can be mounted in several ways pole wall or ceiling The package also includes a drill hole template with detailed mounting instructions to help you with the dril...

Page 4: ...e grounding screw Attach the other end of the grounding wire to the grounded mast Mounting and configuration of this device should be performed by a qualified person Mounting on the mast or pole It s recommended to secure Ethernet cable to the pole using zip ties With the distance from the device approximately 30 cm The installation infrastructure towers and masts as well as the router itself must...

Page 5: ...ening steel clamps with a PH2 screwdriver Guide Ethernet cables through the opening and connect to the Ethernet ports Close bottom latch and secure with a screw A Always make sure to place the unit in an upwards position B It s recommended to use electrical tape to increase friction between materials Mounting unit on the wall ...

Page 6: ...s the button and apply the power then Release the button when a green LED starts flashing to reset RouterOS configuration to defaults Release the button when the LED turns solid green to clear all configuration and bridge all interfaces Release the button after LED is no longer lit 20 seconds to cause a device to look for Netinstall servers required for reinstalling RouterOS over the network Regar...

Page 7: ...st be used with the unit to ensure compliance Innovation Science and Economic Development Canada This device complies with Industry Canada s license exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Le présent appar...

Page 8: ...cualquier interferencia incluyendo la que pueda causar su operacion no deseada Fabricante Mikrotikls SIA Brivibas gatve 214i Riga LV 1039 Latvia País De Origen Letonia Lituania China Republica Popular Estados Unidos De America Mexico Por favor contacte a su distribuidor local para preguntas regionales específicas La lista de importadores se puede encontrar en nuestra página de inicio https mikroti...

Reviews: