2
mikrolift
LiftCell v1.4
When device is on process, if the SIM card is removed and put back again,
device will detect it and remake the SIM card settings. Regarding the problems
of the SIM card, maximum number of attempts are 3. After 3 attempts
(approximately 1 min.), the device is reset if the SIM card is not reactivated.
2.
INx Inputs Connections
Considering the presence of IN6 input, it changes whether IN1, IN2, IN3 and IN4
inputs block or allow dialing.
In case of the presence of IN6 input, IN1, IN2, IN3 and IN4 inputs should be made as
follows:
The device will not make dialing if any of the IN1, IN2, IN3, IN4 inputs are set while
the IN6 input is passive.
When IN7 input is set, it will send address info as SMS. SMS can be sent at
least in every 30 minutes and IN7 input is not considered as set without reset.
3.
Meanings Of Led On The Panel Module
If
red led
is on, it means card has power.
If the
yellow led
is fully
on
, it means the device is ready to use and has
registered numbers.
If the
yellow led
fully
off
, it means the device is processing its opening settings,
which takes approximately 20 seconds, please wait.
If the
yellow led
blinking slowly
(1 sec. On, 1 sec. off), means there is a
problem with SIM card. If it asks for a PIN code, put the SIM card on a phone
and remove the code. If no PIN code is asked, SIM card may be broken or not
be installed.