1. Connecting UNI-DS6 to power supply module
In order to enable the development system to be turned on, it is necessary to provide the appropriate power supply
voltage over an AC/DC connector CN19, Figure 1-1� When the development system is powered, it is necessary to set
switch marked POWER SUPPLY to the ON position� The power supply voltage provided via the CN19 AC/DC connector
may be in a range between 7 and 23V AC or 9 and 32V DC�
A mikroBoard board with different voltage levels can be placed in the mikroBoard
socket provided on the development system� The position of jumper J16 depends
on the voltage level required� When a 5V mikroBoard is placed in the socket it is
necessary to place jumper J16 in the 5V position� If a 3�3V mikroBoard is placed
move jumper J16 in the 3�3V position�
Figure 1-2
: Power supply module
Figure 1-1
: Powering the development system
CN19
AC/DC
R55
3K
R57
0.22
R56
1K
E2
330uF
E3
330uF
E1
U10
D6
4x1N4007
D7
D5
D4
330uF
OFF
ON
C24
220pF
VCC-SW
MC34063A
L2
220uH
D10
MBRS140T3
R5
2K2
LD79
POWER
VCC-5V
SWC
SWE
CT
GND
DRVC
IPK
Vin
CMPR
VCC-BRD
VCC-3.3
VCC-5V
J16
3.3V
5V
{
{
FP2
FERRITE
VCC-5V
VCC-MMC
VCC-3.3
VIN
VOUT
REG1
MC33269DT-3.3
1
3
2
E10
E8
E4
10uF
10uF
10uF
C5
100nF
Figure 1-3
: Power supply module connection schematic