The meter does not count the water flow
Clear turbine (impeller) of the water meter, check the
operation of the water meter, replace the water meter if
necessary.
The water meter cable disconnected
Connect the water meter cable to slot (see picture 4 page 18)
The steering valve programming incorrectly
set
Enter the programming and set the days of regeneration (at
time option) or contact a specialist to correct set the control
valve settings
5. Regeneration
does not start
automatically, and
does not starts after
manual initiation
No power supply or faulty electrical power
Check electrical connections - fuses, plug, switch.
If necessary, regenerate the device manually
Damaged engine
Replace engine
Damaged control board
Replace the control board
6. Water softener
provides hard water
but there is less and
less salt in brine
tank
Water test has been made by the device
dedicated to test KH (carbonate hardness)
Test the water hardness by device dedicated to test total
hardness of water GH
Too little water in the brine tank
Check the setting : time of water filling to the brine tank (see
page 4), set properly and regenerate immediate by pressing
the regeneration button. After regeneration check the amount
of water in the brine tank (there should be about 2-3 liters)
Improperly connected softener
Check the softener connections. IN
–
raw water inlet, OUT
–
treated water outlet (see picture 2 page 7)
The control valve does not draw brine
See the problem 11 - the device does not suck (draws) brine
(dirty injector Contact a specialist or clean the injector)
Softener during regeneration
Wait until the regeneration ends
No salt in brine tank or not enough salt in
brine tank
Prepare a brine solution in a bucket (about 1.5 kg of salt per
6 liters of hot water and mix to dissolve in). Pour the brine
into the brine tank and manually start the regeneration. If
water after regeneration is still hard, replace the resin. Refill
the salt in the brine tank after regeneration.
Salt level in the brine tank should always be above the water
level
The drain is clogged. Softener instead of
sucking brine during the "Brine" cycle, is
pouring water into the tank with the salt.
Then the brine is pouring through the
overflow on the side of the softener
-Check the drain hose. If it is bent, collapsed broken or
clogged, remove the hose from the drain pipe. Check if
nothing is blocking it. Clean the drainage, if necessary,
replace the hose
- Make sure nothing is blocking the sewage pipe, clean the
drainage
Clogged restrictor DLFC - the device does
not draw brine, while pouring water into the
brine tank (water level at the height of the
overflow elbow)
Clean the DLFC restrictor (see picture 5 page 18)