BEDIENUNGSANLEITUNG
englisch
Wasserenthärter
Mini Boy VE
KBS Gastrotechnik GmbH - Johannes-Kepler-Str. 14 - 55129 Mainz
www.kbs-gastrotechnik.de
Stand November 2018
Page 1: ...BEDIENUNGSANLEITUNG englisch Wasserenth rter Mini Boy VE KBS Gastrotechnik GmbH Johannes Kepler Str 14 55129 Mainz www kbs gastrotechnik de Stand November 2018...
Page 2: ...ATED WATER SOFTENER STATION MINIBOY VE Installer Stamp Date of Installation Serial Number Please read the operating manual before startup The manufacturer is not responsible for malfunctions caused by...
Page 3: ...nd statutory regulations 4 1 Description of the device 4 1 1 System structure 4 1 2 Technical description 5 1 3 Control function 6 2 Preparation for installation 6 2 1 Installation preparation plan 6...
Page 4: ...13 The proper name and serial number of the device must be provided with any enquiries and ordering of spare parts Only then an effective and quick reply or order implementation is ensured Transporta...
Page 5: ...g 5 min Standards provisions and statutory regulations 1 Water supplying the device must comply with the requirements of the utility water use regulation 2 Parts that are in contact with treated water...
Page 6: ...oy VE Water hardness English degree French degree PPM German degree Efficiency MiniBoy VE 12 5 18 178 6 10 1950 13 8 19 8 196 5 11 1773 15 21 6 214 3 12 1625 16 3 23 4 232 2 13 1500 17 5 25 2 250 14 1...
Page 7: ...ed see figure on page 7 By turning a screwdriver counter clockwise increase the amount of tap water in the soft water Check the water hardness in the regulated soft water 2 Preparation for installatio...
Page 8: ...for intelligent regeneration down flow A 03 description on page 11 The Valve is preset for the regeneration at 2 a m every 975 liters 0 975 m3 for the water hardness of 20 GH German degrees Depending...
Page 9: ...ons reach Set Recharge Time regeneration hour press button and by using and buttons set the regeneration hour To confirm and save press button Next go to the step Set Residual Water system efficiency...
Page 10: ...the minutes 3 Lastly press and hear a sound Di then finish adjustment 3 Pre Set L DO NOT CHANGE Set Gal L m3 DO NOT CHANGE 4 Pre Set A 03 Intelligent Down Flow DO NOT CHANGE Work Mode DO NOT CHANGE Mi...
Page 11: ...00 35 about 2 8 liter 12 DO NOT CHANGE Fast Rinse Time DO NOT CHANGE DO NOT CHANGE FAST RINSE TIME FOR MINIBOY VE IS 05 00 13 Pre Set 30 days Can be changed Max Days Between Recharges 1 In advanced se...
Page 12: ...wer failure during the filling of the brine tank Check power supply 2 Water is pouring through the top cover of the brine tank during regeneration Drain outlet from the steering valve is connected to...
Page 13: ...ter regeneration check the amount of water in the brine tank there should be about 2 3 liters Improperly connected softener Check the softener connections IN raw water inlet OUT treated water outlet s...
Page 14: ...the brine tank should always be above the water level Improperly connected softener Check the softener connections IN raw water inlet OUT treated water outlet see picture 2 page 7 Softener does not s...
Page 15: ...nse cycle Power failure during refilling water in the brine tank Check power supply Improperly connected softener Check the softener connections IN raw water inlet OUT treated water outlet see picture...
Page 16: ...water did not block the water system before the device Entrance to control valve contaminated with the rest of the installation works Remove all contamination and clean driver Contaminated pre filter...
Page 17: ...utton This will allow the correct re regeneration Clogged drains too small hose to drain Clean outflow into drains and DLFC restrictor see picture 5 page 18 Water pressure drop or not enough water dur...
Page 18: ...d to the wire for power outbound from the steering valve Put the Power adapter to the electrical socket and to the steering valve in the appropriate slot Incorrect supply voltage Connect the power sup...
Page 19: ...99674 email export mijar eu www mijar eu Product card MINIBOY VE PRODUCT CARD Client s adress Date of installation Tested water hardneess Estimated efficiency Date Salt tablets verified supplemented P...