MIHM-VOGT 7203000100 Operating Manual Download Page 52

Page 6

MV-R 100

Version 2.5en - 12/2020

General information

Formatting and symbols

 

$

indicates a general piece of safety information

 

;

indicates that a requirement must be fulfilled

1. 

indicates steps in a series of actions

 

Â

indicates the result of an action

 

y

indicates a list

S1

   

indicates a button

Service address 

Friedrich-List-Straße 8 
D-76297 Stutensee-Blankenloch 
Tel.: +49 (0) 7244 70871-0 
www.mihm-vogt.de

Summary of Contents for 7203000100

Page 1: ...MADE IN GERMANY BETRIEBSANLEITUNG MV R OPERATING MANUAL...

Page 2: ......

Page 3: ...Originalbetriebsanleitung MV R 100 Version 2 5de 12 2020 Friedrich List Stra e 8 D 76297 Stutensee Blankenloch Tel 49 0 7244 70871 0 www mihm vogt de DE...

Page 4: ...tallation 17 Aufstellen 17 Aufstellbedingungen 17 Elektrischer Anschluss 18 Hausinstallation 18 Typenschild 19 Produktbeschreibung 20 Hauptkomponenten des Produkts 20 Grundger t 20 R ckseite Grundger...

Page 5: ...R 100 Seite 3 Ein Aus Taste am Touch Display 38 Pflege und Wartung 39 Serviceprogramme 39 St rungen und Fehlermeldungen 40 Sicherheit 40 bersicht Fehlercodes 41 Au erbetriebnahme 42 Entsorgung 42 Sich...

Page 6: ...des Betreibers Das Ger t wird im gewerblichen Bereich eingesetzt Der Betreiber des Ge r tes unterliegt daher den gesetzlichen Pflichten zur Arbeitssicherheit Neben den Sicherheitshinweisen in dieser...

Page 7: ...ngskonzept f r integrierte Texte und f r Verweise Die folgenden Hinweisarten werden verwendet gefahr Eine unmittelbar drohende Gefahr die zu schweren K rperverlet zungen oder zum Tod f hren k nnte war...

Page 8: ...erheitshinweis hin weist darauf hin dass eine Voraussetzung erf llt sein muss 1 weist auf Handlungsschritte hin weist auf ein Handlungsergebnis hin y weist auf eine Aufz hlung hin S1 weist auf eine Ta...

Page 9: ...beiten am MV R 100 muss pers nliche Schutzausr stung getragen werden um Unf lle und Gesundheitssch den zu vermeiden warnung Elektrische Energie Lebensgefahr durch elektrischen Schlag h Fassen Sie nich...

Page 10: ...ntergut vorsicht Falsche Bedienung Bei Zweckentfremdung falscher Bedienung falschem Anschluss oder nicht fachgerechter Wartung Reparatur durch nicht geschultes Personal wird keine Haftung f r eventuel...

Page 11: ...nden Sie nur Staubsauger mit Feinpartikelfilter HEPA Staub klasse H Im Bereich der Ofent r kann es zum Abtrieb von Isolationsmaterial kom men der als wei er Staub sichtbar ist Diese Ablagerungen sollt...

Page 12: ...n der Verantwortung des Betreibers der Be triebsst tte 3 Kommt es zu einer Fraktur im Sinterprozess durch nicht Einhal tung der empfohlenen Trocknungsprozedur besteht die Gefahr von herausfallenden he...

Page 13: ...n das Ger t leichter getragen werden hinweis Transportsch den Um Personen und Sachsch den zu vermeiden h Transportieren Sie das Ger t nur aufrecht h Stapeln Sie nicht mehrere Ger te bereinander h Stel...

Page 14: ...ernen Sie sie daher erst kurz vor der Erstinbetriebnahme und lagern Sie sie trocken f r eine sp tere Wiederverwendung Lagerung hinweis Temperatursch den Um Temperatursch den zu vermeiden h Lagern Sie...

Page 15: ...st f r Temperaturen bis 1200 C ausgelegt die Innere f r Temperaturen bis 1700 C Ofent r Die Ofent r besteht aus einer keramischen T rf llung Eine in der Antriebsmechanik eingesetzte Rutschkupplung ver...

Page 16: ...Seite 14 MV R 100 Version2 5de 12 2020 Technische Beschreibung Konformit t EG Konformit tserkl rung nach Maschinenrichtlinie 2006 42 EG Anhang II 1 A...

Page 17: ...rden alle Garantieleistungen in solchen F llen ausgeschlossen Durch Einsatz von Ersatz und Verschlei teilen die nicht vom Hersteller bezogen wurden erlischt die Zulassung und Garantie des MV R 100 M g...

Page 18: ...0 Hz Max Leistungsaufnahme 3500 W berspannungskategorie berspannungskategorie II Absicherung Ger teseitig 16 AT Bauseitig Anschluss an einen separaten Stromkreis mit Sicherung 16 A Typ K Z andere Sich...

Page 19: ...inen Mindestabstand von 100 mm um den MV R 100 f r ausreichende K hlung ein vorsicht Entz ndungsgefahr Entz ndung des Bodenbelages durch zerspringende hei e Produkt schale h Achten Sie beim Bodenbelag...

Page 20: ...verbaut werden Der MV R 100 ben tigt f r den elektrisch sicheren Betrieb einen an der Steckdose angeschlossenen Schutzleiter Bei der Wahl des Aufstellungsortes muss beachtet werden dass das beiliegen...

Page 21: ...12 2020 MV R 100 Seite 19 Typenschild 1 8 2 3 4 9 5 7 6 1 Maschinentyp Bezeichnung 6 Referenznummer Mihm Vogt 2 Betriebsspannung 7 Seriennummer 3 Netzfrequenz 8 Baujahr 4 Leistungsangabe 9 Hersteller...

Page 22: ...chreibung Produktbeschreibung Hauptkomponenten des Produkts Grundger t 1 3 2 4 5 6 7 1 3 2 4 5 6 7 1 Grundger t 2 Bedienpanel 3 Einschalttaste Display 4 Statusanzeige 5 T risolation Grundtr ger 6 T ri...

Page 23: ...schluss 4 USB Anschluss Spannungsversorgung 5 V Nennstrom 500 mA Hinweis Der USB Anschluss dient ausschlie lich der bertragung von Daten Backups und SW Updates mittels USB Stick Es d rfen keine andere...

Page 24: ...chritt Starten der ausgew hlten Programme Stoppen eines laufenden Programms Ofent r ffnen schlie en Aktivieren Deaktivieren einer Timer Funktion Aktivieren Deaktivieren einer Vorheizen Funktion Aktivi...

Page 25: ...23 Interaktionssymbole Best tigen einer Interaktion die als Popup erscheint Abbrechen einer Interaktion die als Popup erscheint Info Fehler vorhanden 12H Anzeige AM PM 24H Anzeige Tastatureingabe Datu...

Page 26: ...symbole Steigrate in C min Solltemperatur in C Haltezeit in min Zielzeit in hh mm Ist Temperatur in C Ergebnissymbole Anzeige wenn Prozess fehlerfrei beendet Anzeige wenn Prozess fehlerhaft beendet Wa...

Page 27: ...ss gepr ft werden Schwerwiegender Fehler 2 stelliger Fehlercode Automatischer Prozessabbruch Arbeit ist mit gr ter Wahr scheinlichkeit unbrauchbar Erstinbetriebnahme hinweis Bei Temperaturen unter 15...

Page 28: ...isches Schutzr hrchen 6 3x90 3 T riso Auflage mv r 100 40 4 Auflagevlies 100 f r Sinterschale Das Ger t f hrt nun einen Selbsttest durch und startet den Erstinbe triebnahme Modus 4 Folgen Sie der Men...

Page 29: ...ie an dem gr nen Haken Anhand des grauen Balkens k nnen Sie erkennen wie weit der jeweilige Test be reits fortgeschritten ist Fehler beim Systemtest Falls ein Fehler vorliegt wird der entsprechende Fe...

Page 30: ...Hauptmen Auf dem Bildschirm Hauptmen stehen folgende Men punkte zur Auswahl y Favoriten y Programmoptionen y Einstellungen y Service y QR Code erzeugen y T r ffnen schlie en y Datentransfer Der Berei...

Page 31: ...ppen Sie dazu auf das Symbol neben dem entsprechenden Programm Auf dem Bildschirm Meine Programme k nnen Sie vorhandene Program me zu den Favoriten hinzuf gen oder davon entfernen Ihre favorisierten P...

Page 32: ...programmierbar S1 bis S10 y Lineares Abk hlen Lift ffnet um 30 ab einer Temperatur von 1100 C SpeedPlus Sinterprogramme y Erlaubt eine Eingabe der Heizrate von 1 C min bis 200 C min in vor definierte...

Page 33: ...beim Anw hlen dieser Option schlie t der Lift und der Ofen heizt auf 250 C vor Diese Option wird ohne eine Interaktion durch den Anwender nach Ablauf von 30min beendet Das Vorheizen kann aktiv durch d...

Page 34: ...ationen finden Sie im Kapitel Pflege und Wartung unter dem Abschnitt Serviceprogramme Meine Programme Vom Bildschirm Programme k nnen Sie zum Bildschirm Meine Program me wechseln Hier wird eine bersic...

Page 35: ...emperatureinheit Tippen sie hier um die Temperatureinheit einzustellen Datum Uhrzeit Tippen sie hier um Datum Uhrzeit einzustellen Ger tedaten Tippen sie hier um Information ber ber Typ Baureihe Serie...

Page 36: ...ier um den Systemtest manuell zu starten Fehler Tippen sie hier um die Fehlerliste anzuzeigen und ggf zu l schen Serviceprogramme Tippen sie hier um eines der Serviceprogramme auszuf hren QR Code erze...

Page 37: ...pfehlung f r das Bef llen der Sinterschale Achtung Die SiC Sinterschale kann nur bis zur einer maximal Tempe ratur von 1550 C verwendet werden 1 Bef llen Sie die Sinterschale mit einer ganzen Flasche...

Page 38: ...t zu bertragen muss ein USB Stick 2 0 ohne Passwortschutz vorhanden sein 1 Schlie en Sie den USB Stick an der R ckseite des Ger tes an 2 Der USB Stick wird automatisch als Speichermedium erkannt und S...

Page 39: ...eils ein QS Dokument der letzten 10 durchlau fenen Prozesse zu erstellen Das Dokument finden Sie anschlie end auf dem USB Stick 3 Nach erfolgreicher bertragung der Daten ziehen Sie den USB Stick wiede...

Page 40: ...y Um das Touch Display zu schonen schalten Sie das Display ber die Ein Aus Taste aus Sie m ssen dazu die Taste mindestens f r eine Dauer von 1 Sekunde gedr ckt halten Das Ger t bleibt f r n chste Sint...

Page 41: ...k nnen Einf rbefl ssigkeiten die Lebensdauer der Heizelemente stark verk rzen Serviceprogramme In Abh ngigkeit der Verwendungsh ufigkeit sollte ein Reinigungszyklus durchgef hrt werden Dieser dient d...

Page 42: ...an spannungsf hrende Kabel und Bauteile h Beachten Sie die Unfallverh tungsvorschriften im Umgang mit elektri schem Strom warnung Hei e Oberfl chen Schwere Verbrennungen an den Gliedma en h Greifen Si...

Page 43: ...F42 Thermosensoren Thermosensor auf Platine defekt Service H ndler F400 Thermosensoren Temperatur Sensor K Kurzschluss Service H ndler F401 Thermosensoren Temperatur Sensor K Sensorbruch Service H ndl...

Page 44: ...chalten Sie den MV R 100 aus 2 Trennen Sie den MV R 100 von der Spannungsversorgung 3 Trennen Sie s mtliche Anschl sse vom MV R 100 Entsorgung Sicherheit warnung Freisetzung von Schadstoffen Im Umgang...

Page 45: ......

Page 46: ......

Page 47: ...Translation of Original Operating Instructions MV R 100 Version 2 5en 12 2020 Friedrich List Stra e 8 D 76297 Stutensee Blankenloch Tel 49 0 7244 70871 0 www mihm vogt de EN...

Page 48: ...ng 17 Installation conditions 17 Electrical connection 18 Building installation 18 Rating plate 19 Product description 20 Main components of the product 20 Basic device 20 Back of basic device 21 Expl...

Page 49: ...MV R 100 Page 3 On off button on the touch display 38 Maintenance and servicing 39 Service programs 39 Faults and error messages 40 Safety 40 Overview of error codes 41 Decommissioning 42 Disposal 42...

Page 50: ...n the commercial sector The plant operator responsible for the device is therefore under the legal obligations of industrial health and safety In addition to the safety information in these operating...

Page 51: ...ctions are aimed at trained operating personnel Marking system for integrated text and references The following types of notices are used Danger An imminent risk that could lead to serious physical in...

Page 52: ...piece of safety information indicates that a requirement must be fulfilled 1 indicates steps in a series of actions indicates the result of an action y indicates a list S1 indicates a button Service a...

Page 53: ...s Note Personal protective equipment must be worn for all work on the MV R 100 in order to avoid accidents and damage to health Warning Electrical energy Risk of death from electric shock h Do not tou...

Page 54: ...ing sintering Caution Incorrect operation No liability can be accepted for damage that may be caused by misuse incorrect operation incorrect connections or improper maintenance repair work carried out...

Page 55: ...vacuum cleaners only with fine particle filters HEPA dust class H In the area of the oven door abrasion of insulation material can come about which is visible as white dust You should h wipe away thes...

Page 56: ...ble for providing appropriate safety training 3 If there is a break in the sintering process because of failure to observe the recommended drying procedure there is a risk of hot objects falling out a...

Page 57: ...so that it can be carried more easily Note Transport damage In order to avoid personal injury and transport damage h Transport the device in upright position only h Do not stack several devices on to...

Page 58: ...ge corrosion and other damage Therefore remove it only just before commissioning and store it in a dry place for later use Storage Note Temperature damage To avoid temperature damage h Store the devic...

Page 59: ...elements The outer insulation layer is designed for temperatures up to 1200 C the inner layer for temperatures up to 1700 C Oven door The oven door has a ceramic door filling A slip clutch in the dri...

Page 60: ...of the legislation in the following including the changes which applied at the time of the declaration This declaration of conformity is issued under the sole responsibility of the manufacturer This d...

Page 61: ...ty cover is also excluded in such cases Use of spare and wear parts that were not purchased from the manufacturer invalidates the certification and warranty for the MV R 100 Possible misuse y Deployme...

Page 62: ...er consumption 3500 W Overvoltage category Overvoltage category II Fuse protection In device 16 AT Provided by the customer Connection to a separate electrical circuit with a 16 A type K Z fuse other...

Page 63: ...inimum gap of 100 mm around the MV R 100 to ensure adequate cooling Caution Risk of ignition Ignition of the floor covering due to product tray breaking h Ensure that the floor covering does not have...

Page 64: ...h a tripping current of 30 mA must also be installed For safe electrical operation the MV R 100 requires a protective conductor connected to the socket When selecting the installation location it must...

Page 65: ...2020 MV R 100 Page 19 Rating plate 1 8 2 3 4 9 5 7 6 1 Machine type designation 6 Mihm Vogt reference number 2 Operating voltage 7 Serial number 3 Mains frequency 8 Year of manufacture 4 Output 9 Manu...

Page 66: ...cription Product description Main components of the product Basic device 1 3 2 4 5 6 7 1 3 2 4 5 6 7 1 Basic device 2 Control panel 3 Display on button 4 Status display 5 Door insulation base frame 6...

Page 67: ...switch on off 3 Mains connection 4 USB port power supply 5 V rated current 500 mA Note The USB port is used exclusively for data transmission back ups and software updates on USB stick No other devic...

Page 68: ...to next possible step Back to last step Start selected program Stop running program Open close oven door Activate deactivate a timer function Activate deactivate a pre heating function Activate deacti...

Page 69: ...23 Interaction symbols Confirmation of an interaction that appears as a pop up Cancellation of an interaction that appears as a pop up Info Error present 12H display AM PM 24H display Keyboard input...

Page 70: ...te in C min Set temperature in C Holding time in min Target time in hh mm Actual temperature in C Results symbols Display when process has finished without errors Display when process has finished wit...

Page 71: ...es work must be checked Serious error 2 digit error code Automatic cancellation of process work is very likely to be unusable Commissioning Note In temperatures below 15 C e g after transport allow th...

Page 72: ...ort mv r 100 70 2 Ceramic protection tube 6 3x90 3 Door insulation overlay mv r 100 40 4 Support fleece 100 for sinter tray The device then carries out a self test and starts in commissioning mode 4 F...

Page 73: ...the device off Successfully completed tests are marked with a green tick The green bar indicates the progress of a test Error during system test If there is an error the corresponding error code is di...

Page 74: ...cription Main menu The following items appear on the Main menu screen and can be selected y Favourites y Program options y Settings y Service y Generate QR code y Open close door y Data transfer The S...

Page 75: ...rom the list To do so tap on the symbol next to the program in question On the My programs screen you can add existing programs to your favourites or remove them You can select your favourite programs...

Page 76: ...10 steps freely programmable S1 to S10 y Linear cooling lift opens 30 from a temperature of 1100 C SpeedPlus sintering programs y Allows input of heating rates from 1 C min to 200 C min in pre define...

Page 77: ...for fast sintering programs in particular y Immediately on selection of this option the lift and the oven heats to 250 C This option ends after 30 mins without any interaction with the user Pre heati...

Page 78: ...You can find further information in the Maintenance and servicing section under Service programs My programs You can switch to the My programs screen from the Programs screen This shows an overview of...

Page 79: ...he menu guidance Temperature unit Tap here to set the temperature unit Date time Tap here to set the date time Device details Tap here to obtain information about the model series serial number hardwa...

Page 80: ...s System test Tap here to start the system test manually Error Tap here to display and if necessary clear the error list Service programs Tap here to run the service programs Generate QR code Tap here...

Page 81: ...of zirconium oxide Recommendation for filling the sintering tray Note The SiC sinter tray can only be used up to a maximum tempera ture of 1550 C 1 Fill the sintering tray with a whole bottle of sinte...

Page 82: ...via USB stick To transfer data to the device via USB stick a USB stick 2 0 without password protection must be provided 1 Connect the USB stick to the back of the device 2 The USB stick is automatical...

Page 83: ...Tap here to create a QA document for the last 10 completed processes You will then find the document on the USB stick 3 Following successful transfer of the data remove the USB stick and carry out a...

Page 84: ...e touch display To protect the touch display switch the display off via the on off button You must press and hold the button for at least 1 sec to do this The device is ready for the next sintering pr...

Page 85: ...ing process colouring liquids can shorten the life cycle of the heating elements significantly Service programs A cleaning cycle should be run in accordance with the frequency of use This is used to r...

Page 86: ...live cables and components with wet hands h Observe the accident prevention regulations for working with electric current Warning Hot surfaces Serious burns to the limbs h Do not touch the housing or...

Page 87: ...Thermal sensors Thermal sensor on circuit board defective Service dealer F400 Thermal sensors Temperature sensor K short circuit Service dealer F401 Thermal sensors Temperature sensor S sensor break S...

Page 88: ...MV R 100 off 2 Disconnect the MV R 100 from the power supply 3 Disconnect all connections from the MV R 100 Disposal Safety Warning Release of harmful substances Harmful substances can be inhaled when...

Page 89: ......

Page 90: ...Germany Web www mihm vogt de Mail info mihm vogt de Phone 49 7244 70871 0 Fax 49 7244 70871 20 DENTAL CONSISTENT RELIABLE PRECISE This document was created with utmost care Changes and errors excepte...

Reviews: