QUICKGUIDE
SIGMA ONE
1. Setting the welding current
2. Display of welding current
3. Display of wire feed speed (m/min)
4. Display of current/transfer mode:
- dip transfer
- globular transfer (risk of weld spatter)
- spray transfer
5. Display of material thickness
6. Display of arc length/
shape of welded bead
7. Setting welding voltage
Turn the control knob to trim/set the desired
welding voltage.
8. Display of welding voltage
9. Display of +/- voltage trim
10. Display of selected program
11. Selecting program
Material - wire dimension - gas.
12. Pulse welding
MIG pulse welding on/off (not all versions).
13. Selecting function On/Off
- Spot
Welding in defined spot time
- DUO Plus
TM
Pulsating wire in connection with
synergic MIG
14. Arc adjust
15. Memory function
5 preferred settings.
16. Menu
Standard control panel MIG/MMA
1. Setting parameters
Turn the control knob to set the desired
parameter value.
2. Selecting welding parameter
Turn the control knob to select the desired
welding parameter.
3. Pre-gas (sec.)
4. Softstart (m/min)
5. Hotstart (%)
6. Hotstart time (sec.)
7. Slope down (sec.)
8. Final current time (sec.)
9. Final current (%)
10. Post-gas (sec.)
11. Spot time (sec.)
12. Set current/voltage/process
13. Return
Return to menu.
14. Function settings
Selecting between:
- Spot
- DUO Plus
TM
Setting function parameters
15. Recall of factory settings
Reset the chosen program to factory
settings.
16. Gas
- Setting manual gas/IGC (not all versions)
- Gas test
- Calibration of IGC (not all versions)
17. Machine settings
- Torch
- Service
- Language
- About
18. Arc Power (%)
Setting welding process MIG/MMA -
Process setup
UK 501
1
3817
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
3
12
9
10
11
13
4
5
6
14
15
8
1
2
7
16
1
2
16
10
8
15
11
6
12
13
5
2
18
1
15
17