20
21
Technical data
POWER SOURCE
300
400
550
Mains voltage ±15% (50-60Hz), V
3x400
3x400
3x400
Minimum generator size, kVA
16
27
40
1)
Minimum short-circuit power, MVA
3.7
6.0
9.5
Fuse, A
16
20
35
Mains current effective, A
11.0
17.5
27.2
Mains current max., A
15.4
26.0
39.2
Power 100%, kVA
9.0
12.1
18.9
Power max., kVA
10.7
18.0
27.1
Power open circuit, W
30
30
30
Efficiency, %
85
85
90
Power factor
0.90
0.90
0.90
MIG
MMA
MIG
MMA
MIG
MMA
Current range, A
15-300
15-250
15-400
15-400
15-550
15-550
Duty cycle 100% 20°C, A
290/28.5
250/30.0
345/31.5
345/33.8
475/37.8
475/39.0
Duty cycle max. 20°C, A/%/V
400/65/34.0
400/65/36.0
550/60/41.5
550/60/42.0
Duty cycle 100% 40°C, A/V
220/25.0
220/28.8
300/29.0
300/32.0
430/35.5
430/37.2
Duty cycle 60% 40°C, A/V
240/26.0
230/29.2
370/32.5
370/34.8
510/39.5
510/40.4
Duty cycle max. 40°C, A/%/V
300/25/29.0
250/40/30.0
400/50/34.0
400/45/36.0
550/50/41.5
550/50/42.0
Open circuit voltage, V
50-60
65-70
75-80
2)
Sphere of application
S/CE
S/CE
S/CE
3)
Protection class
IP23S
IP23
IP23
Standards, C
Standards, S
IEC60974-1. IEC60974-5. IEC60974-10 Cl. A
IEC60974-1. IEC60974-10 Cl. A
Dimensions C (HxWxL), mm
Dimensions S (HxWxL), mm
700x260x735
454x260x735
700x260x735
454x260x735
700x260x735
454x260x735
Weight C / S, kg
36.9 / 26
52 / 35
53 / 36
1) This equipment complies with EN / IEC61000-3-12:2014 (/ 2011) provided that the short-circuit power Ssc of the grid at the interface point is greater than or equal to the stated
data in the abovementioned table. It is the responsibility of the installer or user of the equipment to ensure, by consultation with the distribution network operator if necessary,
that the equipment is connected only to a supply with a short-circuit power Ssc greater than or equal to the stated data in the abovementioned table.
2)
S
This machine meets the demand made for machines which are to operate in areas with increased hazard of electric chocks.
3) The machine is designed for indoor and outdoor use according to protection class IP23 / IP23S.
IP23S: The machine may be stored but is not intended to be used outside during precipitation unless sheltered.
WIRE FEED UNIT MWF
Wire feed speed, m/min
0.5-30.0
Torch connection
EURO
Wire-reel diameter, mm
300
Wire spool, kg
5-18
Duty cycle 100 % 40°C, A
430
Duty cycle 60% 40°C, A
500
Duty cycle max. 40°C, A/%
550/50
3)
Protection class
IP23
Wire diameter, mm
0.6-1.6
Gas pressure, MPa (bar)
0.6 (6.0)
Dimensions (HxWxL), mm
457x260x672.5
Weight, kg
14.0
Standards
IEC60974-5,
IEC60974-10 CL. A
COOLING UNIT MCU 1300
Cooling efficiency (1 l/min), W
1300
Cooling efficiency (1.5 l/min), W
1600
Tank capacity, liter
5
Flow, bar - °C - l/min
3.0-60-1.5
Pressure max., bar
5
Standards
IEC60974-2.
IEC60974-10 CL.A
Dimension s (HxWxL), mm
207x260x680
Weight
20
EC DECLARATION OF CONFORMITY
MIGATRONIC A/S
Aggersundvej 33
9690 Fjerritslev
Denmark
hereby declare that our machine as stated below
Type: SIGMA ONE
conforms to directives: 2014/35/EU
2014/30/EU
2011/65/EU
European standards: EN IEC60974-1:2018/A1:2019
EN IEC60974-2:2019
EN IEC60974-5:2019
EN / IEC60974-10:2014/A1:2015
Regulation: 2019/1784/EU
Issued in Fjerritslev 10.02.2021
Kristian M. Madsen
CEO
Summary of Contents for SIGMA ONE 300
Page 7: ...7 Specielle funktioner Setup wizard I II III IV V VI L sefunktion I II III...
Page 12: ...12...
Page 17: ...17 Setup wizard I II III IV V VI Lock function I II III Special functions...
Page 22: ...22...
Page 27: ...27 Sonderfunktionen Wizard Aufstellung I II III IV V VI Sperrfunktion I II III...
Page 32: ...32...
Page 42: ...42...
Page 47: ...47 Setup wizard I II III IV V VI L sfunktion I II III Speciella funktioner...
Page 52: ...52...
Page 57: ...57 Configurazione guidata I II III IV V VI Funzione Blocco I II III Funzioni speciali...
Page 62: ...62...
Page 67: ...67 Speciale functies Wizard instelling I II III IV V VI Vergrendelfunctie I II III...
Page 72: ...72...
Page 77: ...77 Erikoistoiminnot Ohjattu asennustoiminto I II III IV V VI Lukitustoiminto I II III...
Page 82: ...82...
Page 83: ......