![Migatronic SIGMA GALAXY Log Book And Instructions For Use Download Page 9](http://html1.mh-extra.com/html/migatronic/sigma-galaxy/sigma-galaxy_log-book-and-instructions-for-use_1793490009.webp)
8
9
Miga log function
2.3 Miga log settings
The following can be set:
2
Predefined file name. In this example, the file
name is set at ”Test”, and files that will be saved
on the SD-card will now be named Test01, Test02
and so on. Description of the menu for selection
of file name can be seen under “Selection of job
name” in the quick guide.
3
Further information that is added in the upper
part of the log-file.
4
Welding torch travel speed. This input is used for
calculation of ”Heat input” for the welding and is
especially useful in robot or similar applications,
where the torch has a constant travel speed.
5
The time (min. 0.5 s.) from arc ignition until
saving to card.
6
Process factor. This factor is used for calculation
of heat input. Please read “Calculation of heat
input” for setting of the correct value.
2.4 Trip meters
There are two trip meters in the machine that are
independently resettable. Each trip meter indicates arc
time, consumed wire and gas flow since last reset.
2
Reset trip meter 1
4
Reset trip meter 2
2
3
4
5
6
2
4