![Migatronic automation CoWelder UR10E PI350 AC/DC Instruction Handbook Manual Download Page 29](http://html1.mh-extra.com/html/migatronic/automation-cowelder-ur10e-pi350-ac-dc/automation-cowelder-ur10e-pi350-ac-dc_instruction-handbook-manual_1793379029.webp)
Navn CoWelder™
Produkt UR10E-PI350
Version
A – 1.5.2021
Udfærdiget af:
CTM
29
Manually set the robot.
Use the arrows on the screen to fine-adjust
position and angle.
Press OK after manual adjustment.
The waypoint will change from yellow to grey.
Repeat the procedure until all yellow waypoints
have turned green. You can now test the
program.
Test the program by turning the switch to
”Welding off” position, push the green start
button, and the robot will now simulate the
welding process.