Navn CoWelder™
Produkt UR10E-PI350
Version
A – 1.5.2021
Udfærdiget af:
CTM
70
7.2.3.1 Robot arm inspection plan
Check
Monthly Bi-annually
1 Blue lids*
V
X
2 Blue lid screws
F
X
3 Flat rings
V
X
4 Robot cable
V
X
5 Robot cable connection
V
X
6 Robot arm mounting bolts*
F
X
7 Tool mounting bolts*
F
X
8 Screws/bolt on joints*
F
X
V=Visual inspection F=Functional inspection *=Must be checked after heavy collision
1. Move the Robot Arm to HOME position, if possible.
2. Turn off and disconnect the power cable from Control Box.
3. Inspect the cable between Control Box and Robot Arm for any damage.
4. Check the base mounting bolts are properly tightened.
5. Check the tool flange bolts are properly tightened.