- 1 - 

Dear customers and users: 

Thank you for purchasing our products. In order to be able to better use 

this product, please read these instructions carefully before any operation, 
and follow the guide, to avoid any unnecessary trouble during using. 

 

Please keep this instruction manual in a safe place for convenient 

reference and operation. 

 
This instruction manual is subject to any change without further notice, 

and the manufacturer reserves the right of final interpretation. 

 

The appliance is designed for commercial purposes, not for household 

use. 

 
A statement instructing the purchaser to post in a prominent location 

instructions to be followed in the event the user smells gas. This information 
shall be obtained by consulting the local gas supplier. 

 

 

 
 

 

 

 

Summary of Contents for C-F40-LP

Page 1: ...Fryer Operating Instructions Before you begin please read these instructions carefully to use this product correctly to make the product perform ideally and to avoid hazards Models C F40 NG LP C F50...

Page 2: ...anual in a safe place for convenient reference and operation This instruction manual is subject to any change without further notice and the manufacturer reserves the right of final interpretation The...

Page 3: ...3 Manufacturer s Authority and Responsibility 3 4 Parameter Specifications 4 5 Transport and Storage 6 6 Installation and Debugging 6 7 Safety Notices and Precautions 8 8 Operating Instructions 9 9 Cl...

Page 4: ...t safety 2 Brief Introduction The product is a series of gas vertical type fryer in our company production which is novel designed reasonable structured convenient operated durable used and convenient...

Page 5: ...4 4 Parameter Specifications 4 1 Outline Dimensions inch C F40 NG LP C F50 NG LP...

Page 6: ...5 NG LP 4 2 Information of Gas Supply and Burner The minimum supplied gas pressure regulator is factory set at 4 Natural Gas W C and 10 L P Gas W C The external thread of product s intake tube is 3 4...

Page 7: ...storage rainproof measures should be taken 6 Installation and Debugging Any erroneous installation adjustment refit overhaul or maintenance may cause property damage or personal injury The work shall...

Page 8: ...National Fire Protection Association Inc when it comes to requirements for installation of equipment Install legs screw them tightly with flange face see Fig 1 Adjustable stainless steel legs to make...

Page 9: ...om your local gas suppliers When using this equipment safety precautions should always be followed including the following Do not touch high temperature smokestack plate to prevent burns when in using...

Page 10: ...d knob 30 45 seconds Loosen knob if pilot fire is lighting otherwise relight and press knob continually When pilot light burns continually turn knob to ON Fig 7 without press knob Fig 5 Fig 6 Fig 7 8...

Page 11: ...cy depends on the use intensity Daily maintenance can improve the life of the boiler And the climate factors must also be taken into consideration regular cleaning can ensure the best efficiency of eq...

Page 12: ...down after the unit has been turned off before you cleaning Cut off the gas source as not using If the equipment is not used for a long time clean the surface by wiping it with a soft cloth and place...

Page 13: ...g pressure gauge after you accomplish pressure testing then install needle type pressure joint screw arbor Important must screw joint arbor in order to avoid gas escaping Check and adjust thermostat c...

Page 14: ...ld surround thermoelectric couple 1 2 inches the fire must be large enough to keep the thermocouple being red or can not keep the safety valve open 1 Remove controller coppery adjusting cap 2 Adjust c...

Page 15: ...rd a sound of fire 1 Insufficient gas pressure in pipe 1 Contact the local gas supply dept 2 Not match nozzle aperture with gas resources 2 Adjust nozzle diameter 3 Flow of connection pipe is not enou...

Page 16: ...d by other companies our company has the right not to provide warranty service Order replacement parts from authorized representatives and after sale service agency Provide the model no serial no and...

Page 17: ...2 Front panel 1 C F40 NG LP 50 NG LP 21101003032 C F75 NG LP 6 301050011 oil drain valve 1 C F40 NG LP 50 NG LP 75 NG LP 7 301030006 Thermocouple 1 21424 C F40 NG LP 50 NG LP 75 NG LP 301030009 NG 301...

Page 18: ...75 NG LP 18 301170012 intake tube combination valve 1 C F40 NG LP 50 NG LP 75 NG LP 19 301070010 intake tube 1 3 4 C F40 NG LP 50 NG LP 75 NG LP 20 301050008 Black internal and external wire elbow 2...

Page 19: ...5 NG LP Adjustable steel leg 4 pieces 4 pieces 4 pieces Frying basket 1 piece 1 piece 1 piece Flat screen 1 piece 1 piece 1 piece Oil drain pipe 1 piece 1 piece 1 piece External upper smokestack assem...

Page 20: ...vantages of good durability and low maintenance charge But to update some components and necessary maintenance can prolong life length of the products Contact the dealer for assistance In order to avo...

Reviews: