en - English
42
Current carrying capacity table
App
lication
Terminal
assign
ment
Signal
Signal
direction
Current
carrying
capa-
city
Description
PE
Protective earth
PE
Protective earth
3.1
N'
1.0 A Ext. power supply
3.2
L
1.0 A Ext. power supply
P
ayment syst
em
2.1
L'
Appliance ready for operation
2.2
L'
Programme status
2.3
L'
Programme buying impulse
2.4
N'
Time buying signal
2.5
N'
Power supply
2.6
L
Power supply
L' = switched phase, N' = switched neutral conductor
Current carrying capacity of the inputs and outputs
The inputs and outputs are designed specifically for currents, as described in the
“Current carrying capacity table” section.
When connecting external payment systems provided by other manufacturers, the
cable cross-section must not be less than 1.0 mm
2
with a maximum cable length
of 2.50 m.