Liquid dispensing
Dispenser pump
Suction pipe
1 = Hose connection socket (suction side)
2 = Hose connection socket (pressure side)
3 = Leakage outlet (in case of damaged hose)
4 = Suction inlet opening
5 = Level checker for empty indicator
When a dispenser container is empty the
pump and the machine switch them-
selves off automatically.
PROGRAMME --
- - - - - - - -
PROGRAMME STOP
DISPENSING SYSTEM FAULT
Dispensing container 1 empty.
At the same time the machine indicates
a lack of liquid detergent.
The programme will continue automati-
cally once the container has been refilled.
Amount to be dispensed
Follow the detergent manufacturer’s gui-
delines.
Always follow the instructions of the chemical
manufacturer when using cleaning agents
and special application chemicals. Only use
such chemicals for the purpose and in the
situation specified by the manufacturer in
order to avoid the danger of adverse
chemical reactions and material damage.
If in doubt check the suitability of the pro-
duct for use in this machine with the manu-
facturer before using it.
Correct dosage also depends on the viscosity
of the liquid detergent. It should be allowed
to adapt to the normal room temperature be-
fore being used.
Cleaning and care the dispensing system
Rinse the dispensing system through with hot
water every 2 weeks, or before shutting the
dispenser pumps down for any length of time,
to avoid the system getting clogged up.
Rinse out the suction pipes as well with
water.
Put the suction pipes in a container with
warm water, (40 - 50 °C) .
In the Service programme switch in each
pump, until the dispensing system is
rinsed through.
Check the connection points, hoses and
washers for leaks.