Settings
108
Installation requirements
Low water pressure
If the water pressure is below 100 kPa
(1 bar), the programme will be
cancelled and a fault message will
appear.
If the on-site water pressure cannot be
increased, activating this function will
prevent the programme from being
cancelled.
Low water pressure is deactivated as
standard.
Suds cooling
Additional water flows into the drum at
the end of the main wash to cool the
suds down.
Suds cooling takes place when a
Cottons programme with a temperature
of 70 °C or higher is selected.
Suds cooling should be activated:
– to prevent the danger of scalding if
the drain hose is hooked over the
edge of a sink or basin.
– where the drainage pipes do not
comply with DIN 1986.
Suds cooling is deactivated as
standard.
Temperature reduction
At high altitudes water has a lower
boiling point. Miele recommends
activating the reduced temperature
setting at altitudes of 2000 m or above
to prevent water from boiling. The
maximum temperature is reduced to
80 °C even if a higher temperature is
selected.
Temp. reduction is deactivated as
standard.