Electrical connection
,
All electrical work must be performed
by a qualified technician in accordance
with applicable codes and standards.
The machine must only be connected to the
voltage and frequency shown on the data
plate.
The machine is supplied as standard for
connection to a 208 V, 60 Hz, 3 x 20 A,
three-phase electrical supply. Each leg of
power must be 104 - 110 V.
There are further notes on electrical
connection in the installation diagram.
The electric heater rating is factory preset to
15 kW.
The minimum suds level required to activate
heating is 2" (50 mm) column of water.
The motor has an overload protection
switch.
Connection should be made via a suitable,
approved isolator, with an easily accessible
on-off switch to be as an emergency off
switch or for servicing.
WARNING
THIS APPLIANCE MUST BE
GROUNDED
!