Please read the installation diagram and
instructions supplied. They are important
for the proper connection of supplies.
Water connection
The water hook up is by a water valve, which
conforms with local and national regulations.
This work must be carried out by a Miele
authorized service technician.
The inlet pressure hoses supplied with the
machine must be used for connection to the
water supply.
To ensure the hot water inlet hose (marked
194°F/90°C) lasts for many years, do not
hook the hose up to a hot water connection
supplying water hotter than 158°F (70°C).
This hose should only be replaced with a
genuine Miele spare parts.
A water pressure flow rate of 30 psi - 145 psi
(2 -10 bar) is required.
Water taken into the machine must not
exceed a temperature of 158°F (70°C).
Connection to cold water only:
see, the supplied installation diagram.
Drainage system
Possible connections:
1. Directly into a sink
: hook the hose over
the edge of the sink and secure it firmly
(e.g. by tying the hose to the water
faucet.)
2. To a stand pipe:
place the drain hose into
a 1
½
" stand pipe and firmly secure it.
3. To a floor drain:
The machine is
equipped with an air gap/anti-siphoning
system so that no minimum drain height
is required.
– The machine drains using a pump with a
maximum delivery height of 3 ft.
– The elbow on the end of the drain hose
can be turned or removed if necessary.
– Make sure there are no kinks in the drain
hose.
– If desired, the drain hose may be
extended to run 16 ft maximum as long as
the 3 ft height is not exceeded. Hose
extensions are available from your dealer
or Miele’s Technical Service Department.
Plumbing