Electrical connection U.K.
All electrical work should be carried out
only by a suitably qualified and
competent person, in strict accordance
with national and local safety
regulations.
The appliance is supplied with a mains
cable with moulded plug for connection
to a 230-240V mains supply.
The
voltage, rated load and fuse rating
are given on the data plate
. Please
ensure these match the household
mains supply.
Connection should be made via a fused
plug and suitable switched socket
which is easily accessible after
installation.
For extra safety it is advisable to install
a residual current device (RCD), with a
trip current of 30 mA (in accordance
with DIN VDE 0664, VDE 0100 Section
739).
Do not connect via an extension lead.
Important
The wires in the mains lead are
coloured in accordance with the
following code:
Green/yellow
= earth
Blue
= neutral
Brown
= live
Where it is necessary to change plugs,
if the colours of the wires in the mains
lead of this appliance do not
correspond with the coloured markings
identifying the terminals of your plug,
proceed as follows:
The wire which is coloured green and
yellow must be connected to the
terminal in the plug which is marked
with the letter E or by the earth symbol
z
or coloured green, or green and
yellow.
The wire which is coloured blue must
be connected to the terminal in the
plug which is marked with the letter N
or coloured black.
The wire which is coloured brown must
be connected to the terminal in the
plug which is marked with the letter L or
coloured red.
WARNING: THIS APPLIANCE
MUST BE EARTHED
Ensure power is not supplied to the
appliance while installation work is
being carried out.
Installation and connection
62
Summary of Contents for W 487 WPS
Page 66: ...66 ...
Page 67: ...Programmable functions for changing standard settings ...
Page 74: ...74 ...
Page 75: ...75 ...