Installation
*
I
N
S
T
A
L
L
A
T
I
O
N
*
64
Loosen the lug and pull the plug out.
Loosen the strain relief screw
and
unlock the casing on both sides
.
Open the casing.
Remove the stopper.
Exchange the bridge
for the con-
nection cable of the switching sys-
tem.
Close the casing.
Tighten the strain relief screw.
Reinsert the plug.
Connecting the e-box
Connect the operating voltage and
fan control cables to the e-box and
the fan.
Connect the control unit cable to the
e-box.
The socket positions are designed in
such a way that they cannot be mixed
up.
Connect the downdraft extractor to
the mains.
Check that the downdraft extractor
works.
Sealing the gaps
Seal the gaps between the individual
SmartLine elements, and between the
flush-mounted SmartLine elements
and the worktop, with a silicone seal-
ant that is heat-resistant to at least
160 °C.
Unsuitable sealant can damage nat-
ural stone.
For natural stone worktops and nat-
ural stone tiles, only use silicone
sealant that is specially formulated
for natural stone.
Please follow the manufacturer's in-
structions.