Installation
*
I
N
S
T
A
L
L
A
T
I
O
N
*
63
E-box
a
Mains connection cable
b
Connection to window contact
c
Electrical connection socket for the
fan operating voltage cable
d
Electrical connection socket for the
fan control cable
e
Electrical connection socket for the
control unit cable
Connection to window contact, if re-
quired
The window contact connection
is live!
Danger of electric shock!
Disconnect the countertop extractor
from the mains before connecting
the switching system.
The connection cable of the switch-
ing system must only be connected
by a suitably qualified and compet-
ent electrician.
The connection cable of the switch-
ing system must comply with type
H03VV-F 2 x 0.75 mm
2
and must not
exceed 2.0 m in length.
The switching system must be
equipped with a potential-free con-
tact suitable for 230 V, 1 A. The ex-
tractor is switched off when the
switch is open.
Only use DIPT-approved and tested
radio switching systems (e.g. window
contact switches, pressure switches)
and have them approved by author-
ised specialists (e.g. building regula-
tions inspector).
The switching system must be suit-
able for use with a BLDC motor.
You will need the appropriate ex-
ternal switching system documents
to safely connect and operate the
switch.