background image

PWM 507 

en-AU, NZ 

 = standard, 

 = optional, + = only on request, - not available 

 

11 284 900/00 

Technical data 

 

PWM 507 DV 

PWM 507 DP 

PWM 507 DV 
Hygiene/Special 

PWM 507 DP 
Hygiene/Special 

Drum volume 

64 

64 

64 

64 

Load capacity 

kg 

7.0 

7.0 

7.0 

7.0 

Door opening diameter 

mm 

300 

300 

300 

300 

Max. spin speed 

rpm 

1600 

1600 

1600 

1600 

g factor 

 

704 

704 

704 

704 

 

 

 

 

 

 

E l e c t r i c a l   c o n n e c t i o n   ( E L )  

 

 

 

 

 

Standard voltage (AU, NZ) 

 

1N AC 230 V 

1N AC 230 V 

1N AC 230 V 

1N AC 230 V 

Frequency 

Hz 

50 

50 

50 

50 

Total rated load 

kW 

5.5 

5.5 

5.5 

5.5 

Fuse rating 

1 x 25 

1 x 25 

1 x 25 

1 x 25 

Supply cable min. cross-section  

mm² 

3 x 2.5 

3 x 2.5 

3 x 2.5 

3 x 2.5 

Supply cable without plug 

 

 

 

 

 

Length of supply cable 

mm 

2000 

2000 

2000 

2000 

 

 

 

 

 

 

Standard voltage (AU, NZ) 

 

1N AC 230 V 

1N AC 230 V 

1N AC 230 V 

1N AC 230 V 

Frequency 

Hz 

50 

50 

50 

50 

Total rated load 

kW 

2.85 

2.85 

2.85 

2.85 

Fuse rating 

1 x 16 

1 x 16 

1 x 16 

1 x 16 

Supply cable min. cross-section  

mm² 

3 x 1.5 

3 x 1.5 

3 x 1.5 

3 x 1.5 

Supply cable with plug 

 

 

 

 

 

Length of supply cable 

mm 

2000 

2000 

2000 

2000 

 

 

 

 

 

 

C o l d   w a t e r   ( K W )

 

 

 

 

 

 

Permissible water flow pressure 

kPa 

100 

– 1000 

100 

– 1000 

100 

– 1000 

100 

– 1000 

Required flow rate (cold water connection only) 

l/min 

11 

11 

11 

11 

Required flow rate (with additional hot water connection) 

l/min 

10 

10 

10 

10 

Connection to be provided on site, external thread according to AS 3688 (flat seal)

 

Inch

 

¾“

 

¾“

 

¾“

 

¾“

 

Connection hose ½" with ¾" threaded union 

 

 

 

 

 

Connection hose length 

mm 

1550 

1550 

1550 

1550 

 

 

 

 

 

 

H o t   w a t e r   ( W W )

 

 

 

 

 

 

Max. water intake temperature 

°C 

70 

70 

70 

70 

Permissible water flow pressure 

kPa 

100 

– 1000 

100 

– 1000 

100 

– 1000 

100 

– 1000 

Required flow rate 

l/min 

11 

11 

11 

11 

Connection to be provided on site, external thread according to AS 3688 (flat seal)

 

Inch

 

¾“

 

¾“

 

¾“

 

¾“

 

Connection hose ½" with ¾" threaded union 

 

 

 

 

 

Connection hose length 

mm 

1550 

1550 

1550 

1550 

 

 

 

 

 

 

D r a i n   v a l v e   ( D V )

 

 

 

 

 

 

Connection (ext. diameter) 

 

mm

 

75 (DN70)

 

-

 

75 (DN70)

 

-

 

Max. drainage temperature 

°C 

90 

 

90 

 

Max. transient flow rate 

l/min 

62 

62 

 

 

 

 

 

 

D r a i n   p u m p   ( D P )

 

 

 

 

 

 

Hose connection (external diameter)  

mm 

22 (DN22) 

22 (DN22) 

Max. drainage temperature 

°C 

90 

90 

On-site hose sleeve (int. diameter x length) 

mm 

22 x 30 

22 x 30 

Max. transient flow rate 

l/min 

26 

26 

Max. delivery head (from lower edge of machine)

 

mm

 

-

 

1000

 

-

 

1000

 

Drain hose DN 22 with connector (supplied as standard) 

 

 

 

Connection hose length 

mm 

1500 

1500 

 

 

 

 

 

 

E q u i p o t e n t i a l   b o n d i n g   ( P A)    

 

 

 

 

 

Appliance connection (separate kit required) 

 

 

 

 

 

 

 

 

 

 

 

X C I   b o x   L G   i n t e r f a c e  

 

 

 

 

 

 

 

 

 

 

 

P e a k   l o a d / e n e r g y  m a n a g e m e n t   ( S L A )

 

 

 

 

 

 

Appliance connection (with XCI box LG)

 

 

 

 

 

 

Summary of Contents for PWM 507 DP Hygiene/Special

Page 1: ...PWM 507 DV DP PWM 507 DV DP Hygiene Special It is essential to read the operating and installation instructions before installation and commissioning This prevents both personal injury and damage to the appliance en AU NZ 11 284 900 00 ...

Page 2: ...rofessional com au Miele Global Headquarters Germany Carl Miele Straße 29 33332 Gütersloh Federal Republic of Germany Legend Connection required Connection optional or required depending on model DV Drain valve KW Cold water connection AW Waste water connection DP Drain pump B Appliance anchoring PA Equipotential bonding DOS Dispenser connection SLA Peak load connection EL Electrical connection UG...

Page 3: ...PWM 507 en AU NZ 11 284 900 00 3 Appliance dimensions F F F F F F F F EL KGA SLA XKM DP DV KW WW DOS PA ...

Page 4: ...PWM 507 en AU NZ 4 11 284 900 00 Installation EL WW KW KG DV DP KG WW KW EL DP DV KGA SLA EL WW KW KG DP UO UG DV UO UG KG WW KW EL DP DV KGA SLA ...

Page 5: ...PWM 507 en AU NZ 11 284 900 00 5 Washer dryer stack F F EL WW KW DP DV EL KGA SLA WW KW DV F F APCL APCL ...

Page 6: ...PWM 507 en AU NZ 6 11 284 900 00 Installation 305 145 5 145 5 681 1031 B B B B BS B B 305 145 5 145 5 305 1031 B B 148 148 305 148 148 BS ...

Page 7: ...PWM 507 en AU NZ 11 284 900 00 7 Installation UO UG B B UO UG B B UO UG B B B B UO UG B B B B ...

Page 8: ...00 Required flow rate cold water connection only l min 11 11 11 11 Required flow rate with additional hot water connection l min 10 10 10 10 Connection to be provided on site external thread according to AS 3688 flat seal Inch Connection hose with threaded union Connection hose length mm 1550 1550 1550 1550 Hot water WW Max water intake temperature C 70 70 70 70 Permissible water flow pressure kPa...

Page 9: ...ength mm 12 x 60 12 x 60 12 x 60 12 x 60 Plinth floor anchoring to be provided on site Appliance installation on on site base concrete or masonry Min plinth installation footprint W D mm 600 650 600 650 600 650 600 650 Wood screws according to DIN 571 mm 6 x 50 6 x 50 6 x 50 6 x 50 Wall plugs diameter x length mm 8 x 40 8 x 40 8 x 40 8 x 40 Appliance data Overall appliance dimensions H W D mm 854 ...

Page 10: ...f the earthing conductor including determining the correct fuse amperage must be carried out by a qualified electrician as they are familiar with the pertinent regulations and the specific requirements of the electric utility company The appliance must not be connected to devices such as timers which would switch it off automatically References to cable cross sections in the technical data refer o...

Page 11: ... required for connecting a payment system can be carried out during the initial commissioning process After initial commissioning changes can only be made by your Miele dealer or by Miele Professional Service Interface The appliance can be fitted with an XKM 3200 WL PLT communication module This module can be used as a Wi Fi or LAN interface The LAN interface provided via the module complies with ...

Reviews: