background image

 
 

 

11 284 900/00 

Miele Australia Pty. Ltd. 

ACN 005 635 398 

ABN 96 005 635 398 

Melbourne: 

1 Gilbert Park Drive 

Knoxfield, VIC 3180 

Telephone: 1300 731 411 

[email protected] 

 

www.miele-professional.com.au 

[email protected] 

 

Miele New Zealand Limited 

IRD 98 463 631 

Level 2, 10 College Hill 

Freemans Bay 

Auckland 1011 

New Zealand 

Telephone: 

0800 4 MIELE 

 

 

(0800 464 353) 

www.miele-professional.com.au 

[email protected] 

 

Miele Global Headquarters 

Germany 

Carl-Miele-Straße 29 

33332 Gütersloh 

Federal Republic of Germany 

 

 

Legend: 

 

Connection required 

 

Connection optional or required, 
depending on model 

DV 

Drain valve 

KW 

Cold water connection 

AW 

Waste water connection 

DP 

Drain pump 

Appliance anchoring 

PA 

Equipotential bonding 

DOS  Dispenser connection 

SLA 

Peak load connection 

EL 

Electrical connection 

UG 

Box plinth 

Appliance feet, adjustable 

UO 

Open plinth 

KG 

Payment system 

APCL  Washer-dryer stacking kit 

KGA  Payment system connection 

WW 

Hot water connection 

 

 

XKM  Communication module 

 

 
 

Technical changes and errors excepted. 

Summary of Contents for PWM 507 DP Hygiene/Special

Page 1: ...PWM 507 DV DP PWM 507 DV DP Hygiene Special It is essential to read the operating and installation instructions before installation and commissioning This prevents both personal injury and damage to the appliance en AU NZ 11 284 900 00 ...

Page 2: ...rofessional com au Miele Global Headquarters Germany Carl Miele Straße 29 33332 Gütersloh Federal Republic of Germany Legend Connection required Connection optional or required depending on model DV Drain valve KW Cold water connection AW Waste water connection DP Drain pump B Appliance anchoring PA Equipotential bonding DOS Dispenser connection SLA Peak load connection EL Electrical connection UG...

Page 3: ...PWM 507 en AU NZ 11 284 900 00 3 Appliance dimensions F F F F F F F F EL KGA SLA XKM DP DV KW WW DOS PA ...

Page 4: ...PWM 507 en AU NZ 4 11 284 900 00 Installation EL WW KW KG DV DP KG WW KW EL DP DV KGA SLA EL WW KW KG DP UO UG DV UO UG KG WW KW EL DP DV KGA SLA ...

Page 5: ...PWM 507 en AU NZ 11 284 900 00 5 Washer dryer stack F F EL WW KW DP DV EL KGA SLA WW KW DV F F APCL APCL ...

Page 6: ...PWM 507 en AU NZ 6 11 284 900 00 Installation 305 145 5 145 5 681 1031 B B B B BS B B 305 145 5 145 5 305 1031 B B 148 148 305 148 148 BS ...

Page 7: ...PWM 507 en AU NZ 11 284 900 00 7 Installation UO UG B B UO UG B B UO UG B B B B UO UG B B B B ...

Page 8: ...00 Required flow rate cold water connection only l min 11 11 11 11 Required flow rate with additional hot water connection l min 10 10 10 10 Connection to be provided on site external thread according to AS 3688 flat seal Inch Connection hose with threaded union Connection hose length mm 1550 1550 1550 1550 Hot water WW Max water intake temperature C 70 70 70 70 Permissible water flow pressure kPa...

Page 9: ...ength mm 12 x 60 12 x 60 12 x 60 12 x 60 Plinth floor anchoring to be provided on site Appliance installation on on site base concrete or masonry Min plinth installation footprint W D mm 600 650 600 650 600 650 600 650 Wood screws according to DIN 571 mm 6 x 50 6 x 50 6 x 50 6 x 50 Wall plugs diameter x length mm 8 x 40 8 x 40 8 x 40 8 x 40 Appliance data Overall appliance dimensions H W D mm 854 ...

Page 10: ...f the earthing conductor including determining the correct fuse amperage must be carried out by a qualified electrician as they are familiar with the pertinent regulations and the specific requirements of the electric utility company The appliance must not be connected to devices such as timers which would switch it off automatically References to cable cross sections in the technical data refer o...

Page 11: ... required for connecting a payment system can be carried out during the initial commissioning process After initial commissioning changes can only be made by your Miele dealer or by Miele Professional Service Interface The appliance can be fitted with an XKM 3200 WL PLT communication module This module can be used as a Wi Fi or LAN interface The LAN interface provided via the module complies with ...