Water connections
Cold water connection
Required flow pressure
100–1000 kPa (1–10 bar)
Maximum flow rate (if no hot water and hard water supply)
74 (79,5*) l/min
Maximum flow rate
26 (31,5*) l/min
Threaded union required (to be provided by customer in accordance with DIN 44991, flat
sealing)
3/4"
Length of water inlet hose supplied
1550 mm
*With liquid dispensing
Hot water connection (for variants with reduced heater rating)
Hot water connection (for variants with reduced heater rating)
90°
Required flow pressure
100–1000 kPa (1–10 bar)
Maximum flow rate
74 (79,5*) l/min
Threaded union required (in accordance with DIN 44991, flat sealing)
1"
Length of water inlet hose supplied
1550 mm
Hard water connection
Required flow pressure
100–1000 kPa (1–10 bar)
Maximum flow rate
32 l/min
Threaded union required (in accordance with DIN 44991, flat sealing)
3/4"
Length of water inlet hose supplied
1550 mm
Waste water (drain valve)
Maximum waste water temperature
95 °C
Machine-side drain connection (external diameter)
HT DN 70
On-site drain (internal diameter)
75 x 1,9 x 110 mm (Muffe DN 70)
Maximum flow rate
200 l/min
A vented combined pipe is required to drain the waste water. If several machines are connected to a single drain pipe, this should be
sufficiently large to allow all machines to drain simultaneously.
Securing the machine
Fittings
4 x wood screws DIN 571 (
Ø
x length)
12 mm x 90 mm
4 x plugs (
Ø
x length)
16 mm x 80 mm
Fixing the machine in place is absolutely essential.
Fastenings for floating screed must be supplied by the customer on site.
Emissions
Average heat dissipation rate to installation room
4,7 MJ/h
Emission sound pressure level in the workplace
78 dB(A) re 20 µPa
Sound power level, washing
60,3 dB (A) re 1 pW
Sound power level, spinning
82,2 dB (A) re 1 pW
Summary of Contents for PW 6241 EL
Page 2: ...2 de 4 en 21 fr 37 es 53 ru 70 it 87 ...
Page 15: ...de Aufstellung INSTALLATION 15 Abmessungen ...
Page 31: ...en Installation INSTALLATION 31 Dimensions ...
Page 47: ...fr Installation INSTALLATION 47 Dimensions ...
Page 64: ...es Emplazamiento INSTALLATION 64 Medidas ...
Page 81: ...ru Установка INSTALLATION 81 Размеры ...