en - Installation notes
*INSTALLATION*
10
BSS peak-load
negotiation kit
The washing machine can be connected to a peak-load shut-off or an
energy management system using a BSS peak-load negotiation kit
which is available as an optional accessory.
The peak-load cut-out monitors the energy consumption of a sys-
tem and deactivates individual pieces of equipment temporarily in
order to ensure that certain total load limits are not exceeded. Monit-
oring is externally controlled.
The kit provides three signal contacts and a neutral conductor via a
terminal block. The terminal block is marked with “a”, “b”, “c”, and “d”.
a
Output signal, start of machine operation
b
Output signal, machine heating request
c
Peak-load input signal, machine heating deactivated
d
Neutral conductor
When the peak-load function is activated the current programme is
stopped and a message appears in the display on the washing ma-
chine. At the end of the peak-load function the programme resumes
automatically.
XKM RS232 com-
munication mod-
ule
The serial interface RS-232 can be retrofitted to the washing machine
via an XKM RS 232 (optional accessory available from Miele). This
communication module must only be used with Miele Profes-
sional machines that are fitted with an appropriate slot for the mod-
ule.
The data interface provided via communication module
XKM RS232 complies with SELV (Safety Extra Low Voltage) in ac-
cordance with EN 60950.
Appliances connected to this interface must also be SELV compli-
ant.
Communication module XKM RS 232 is supplied with a connection
cable and a D-sub-connector.
Vapour and foam
venting kit
(APWM 063)
If excessive suds form, foam may escape from the vapour vent. To re-
move the foam, an optional vapour and foam venting kit (BWS) can
be used.
Summary of Contents for PW 6241 D
Page 2: ...2 en 4 cs 21 hu 38 pl 56 pt 74 tr 92 ...
Page 15: ...en Installation INSTALLATION 15 Dimensions ...
Page 32: ...cs Umístění INSTALLATION 32 Rozměry ...
Page 50: ...hu Installálás INSTALLATION 50 Méretek ...
Page 68: ...pl Ustawienie INSTALLATION 68 Wymiary ...
Page 86: ...pt Instalação INSTALLATION 86 Dimensões ...