Cold water
(Soft water)
Min. flow pressure
kPa
100
Max. pressure
kPa
1000
Max. throughput
l/min
11
On-site connection thread according to DIN 44 991
Inch
¾" external thread
Length of connection hose
(supplied) 1 connection hose)
mm
1550
Water requirements (average for 60°C programme)
Standard connection (hot water fill)
l/h
approx. 70
Additional requirements if hot water supply is not available.
If connected to grey water supply (optional), subtract from
cold water volume.
Hot water
(Soft water)
Max. temperature
°C
70
Min. flow pressure
kPa
100
Max. pressure
kPa
1000
Max. throughput
l/min
11
On-site connection thread according to DIN 44 991
Inch
¾" external thread
Length of connection hose
(supplied) 1 connection hose)
mm
1550
Water requirements (average for 60°C
programme)
l/h
approx. 70
Machine can be connected to a hot water supply line with a
temperature of 70°C to max. 85°C. This requires a separate
inlet hose. This additional inlet hose is available from Miele
Spares. The machine must also be reprogrammed by Miele
Service or an authorised agent.
If hot water is not available, connect hot water hose to cold
water valve!
Waste water
Model versions
with drain pump
Max. temperature
°C
70
Drain hose (int. diameter)
mm
22 [DN 22]
On-site hose connector for drain hose
(int. diameter x length)
mm
22 × 30
Max. transient throughput
l/min
26
Drain pump head height (from floor level)
mm
1000
Vented drainage required. If ventilation is insufficient, fit Miele
kit, Mat. No. 05238090.
Drain manifolds serving several machines must be of suffi-
cient cross-section.
Fittings (supplied)
Miele US 6008 plinth
4 × metal angled brackets
(to secure machine to plinth)
4 × screws DIN 571 (Ø × length)
mm
6 × 50
4 × rawl plugs (Ø × length)
mm
8 × 40
Machine must be bolted to the floor!
Fixing materials for a floating screed floor are to be provided
on site.
mm
6 × 50
mm
8 × 40
On concrete platform
2 × clamps
2 × screws DIN 571 (Ø × length)
2 × rawl plugs (Ø × length)
Machine must be bolted to the floor!
Fixing materials for a floating screed floor are to be provided
on site.
Machine data
Unit width
mm
700
Machine depth
mm
727
Unit height
mm
1020
Casing width
mm
692
Casing depth
mm
690
mm
720
mm
1100
Minimum width of delivery access to installation site
Minimum rear wall gap (measured to front of machine)
Wall gap (to front of machine)
Minimum gap ensures sufficient space for maintenance and
servicing.
mm
900
kg
140
N
2750
N
1960
N
790
Hz
22
Net weight
Dynamic floor load, max.
Static floor load, max.
Dynamic load, max.
Drum frequency, max.
Average heat dissipation
(dependent on ambient room temperature and
programme selected)
W
not yet available
Sound pressure (re 20 mPA),
workplace-related (at distance of 1 m and height of 1.6 m)
dB (A)
<70
Installation should only be carried out by authorised fitters in accordance with valid regulations!