Technical datasheet: PW 6088 EL LP
Date: 01.04.2014
Page: 7
Technical datasheet
Washer-extractor:
Heating:
PW 6088 LP
Electric (EL)
Legend:
Abbreviations in bold type:
Connection required
en - AU
Abbreviations in circle with dashes:
Connection optional or required depending on model version
Optional extras:
UM
Miele plinth
US 6008 (US = plinth with drawer)
Height
mm
320
Width
mm
692
Depth
mm
685
BS
Concrete plinth
Quality and density of concrete must comply with load. Con-
crete plinth must be firmly secured to floor!
Recommended height
mm
300
Minimum height
mm
70
Recommended width
mm
≥700
Recommended depth
mm
≥700
Machine connections:
Electrical
connection
1. Standard voltage (as supplied)
V
1N AC 230
Frequency
Hz
50
Rated load
kW
5.5
Fuse rating
A
1 × 25
Supply lead cross-section
mm²
3 × 2.5
Length of supply lead
mm
2170
Supply lead without plug (supplied)
Electrical connection must comply with national regula-
tions.
A wall socket or mains isolator must be easily accessible
after installation.
Reinstallation of the supply point, changes to the equip-
ment or checks on the protective conductor, including de-
termination of correct fuse rating, should only be per-
formed by a properly trained electrician.