background image

 

Technical datasheet: PW 6088 EL LP 

Date: 01.04.2014 

 

Page: 7 

 

 

 
 

Technical datasheet 

 

 
 

 

 

 

 

 

Washer-extractor: 
Heating: 
 

PW 6088 LP 
Electric (EL) 

 
 

 

Legend: 

 

Abbreviations in bold type:

 

Connection required 

en - AU 

 

 

 

Abbreviations in circle with dashes:

 

Connection optional or required depending on model version 

 

 

 

 

Optional extras: 

 
UM 

 

Miele plinth 

US 6008 (US = plinth with drawer) 

 

 

Height 

mm 

320 

 

Width 

mm 

692 

 

 

Depth 

mm 

685 

 

BS 

 

Concrete plinth 

Quality and density of concrete must comply with load. Con-
crete plinth must be firmly secured to floor! 

 

 

 

 

Recommended height 

mm 

300 

 

 

Minimum height 

mm 

70 

 

 

Recommended width 

mm 

≥700

 

 

 

Recommended depth 

mm 

≥700

 

 

Machine connections: 

 

 

 

Electrical 

connection 

1. Standard voltage (as supplied)  

1N AC 230  

Frequency 

Hz 

50 

 

Rated load 

kW 

5.5 

 

Fuse rating 

1 × 25 

 

 

Supply lead cross-section 

mm² 

3 × 2.5 

 

 

Length of supply lead 

mm  

2170 

 

 

Supply lead without plug (supplied) 

 

 

 

 

 

 

 

 

 

Electrical connection must comply with national regula-
tions. 
A wall socket or mains isolator must be easily accessible 
after installation. 
Reinstallation of the supply point, changes to the equip-
ment or checks on the protective conductor, including de-
termination of correct fuse rating, should only be per-
formed by a properly trained electrician. 

 

 

 
 

 

Reviews: