background image

PT 8807 D 

en - US 

 

Machine dimensions 

( m e a s u r e m e n t s   i n   i n c h e s )

 

 

 

 

 

Summary of Contents for PT 8807 D (Steam)

Page 1: ...Installation Plan Tumble dryer PT 8807 D Steam en US 05 15 M Nr 10 126 430 ...

Page 2: ...It is essential to read the operating and installation instructions before installing commissioning or using the machine This avoids the risk of accidents or damage All rights reserved M Nr 10 126 430 2 ...

Page 3: ...PT 8807 D en US Machine dimensions measurements in inches 3 ...

Page 4: ...en US PT 8807 D Machine connections measurements in inches 4 ...

Page 5: ...PT 8807 D en US Machine connections measurements in inches 5 ...

Page 6: ...en US PT 8807 D Standard installation measurements in inches 6 ...

Page 7: ...PT 8807 D en US Option Installation on concrete platform BS measurements in inches 7 ...

Page 8: ...en US PT 8807 D Machine dimensions measurements in millimeters 8 ...

Page 9: ...PT 8807 D en US Machine connections measurements in millimeters 9 ...

Page 10: ...en US PT 8807 D Machine connections measurements in millimeters 10 ...

Page 11: ...PT 8807 D en US Standard installation measurements in millimeters 11 ...

Page 12: ...en US PT 8807 D Option Installation on concrete platform BS measurements in millimeters 12 ...

Page 13: ...eam valves or as pneumatic steam valves Pneumatic steam valve PND Regulatable steam pressure 0 145 psi 0 1000 kPa Connection gauge Supply point and pneumatic valve controls must be provided on site Machine connections Electrical connection Voltage 3 AC 208 V Frequency 60 Hz Rated load 6487 4 BTU h 1 9 kW Fuse rating 3 x 10 A Connection cable min cross section 4 x AWG 16 4 x 1 5 mm Connection cable...

Page 14: ...ans no condensate is left in the heater element Installation of an inverted bucket steam trap is recommended Air outlet Max nominal air flow in vented mode 39200 cu ft h 1110 m h Max permissible pressure loss 6 3 psf 300 Pa Connection on machine side ext diameter 5 15 16 150 mm Connection pipe provided on site int diameter 5 15 16 150 mm Max temperature 176 F 80 C As relative humidity inside the v...

Page 15: ...47 1 4 1200 mm Casing depth 50 3 8 1279 mm Minimum width of delivery access to installation site 48 1220 mm Recommended rear wall gap measured to front of machine 70 7 8 1800 mm Min wall gap to rear edge of lid 19 3 4 500 mm Net weight 701 1 lbs 318 kg Dynamic floor load max 834 lbf 3708 N Average heat dissipation depends on ambient room temperature and selected program 3692 BTU h 1082 W Noise lev...

Reviews: