background image

 

Installationsplan / Installation plan: PT 8803/8805/8807 
Datum / Date: 12.01.2011 

  Seite / Page: 9 

 

 

 
 

Technical datasheet 

 

 
 

 

 

 

 

 

 

Tumble dryer:  
Heating: 
 

PT 8803/8805/8807 

Electric (EL) 

 

 

Legend: 

 

Abbreviations in bold type:

 

Connection required 

en - GB 

 

 

 

Abbreviations in circle with dashes:

 

Connection optional or required depending on model version 

 

Optional extras: 

BS 

Concrete plinth 

Quality and density of concrete must comply with load. 
Concrete plinth must be firmly secured to floor! 

 

 

Recommended height 

mm 

100 

Minimum height 

mm 

50 

 

 

Width min. 

mm 

1200 

 

 

Width:min. 

mm 

1400 

 
 

Machine connections: 

 

Electrical 

connection 

1. Standard voltage (as supplied)  

 

3N AC 380 - 415  

Frequency 

 

Hz 

50 

Rated load 

 

kW 

34.4 – 40.7 

 

 

Fuse rating 

 

3 × 63 

 

 

Connection cable, min. cross-section 

 

mm² 

5 × 16 

 

 

Cable screw connector 

 

 

M 50 

 

 

Connection cable (to be ordered separately) 

 

 

 

 

 

2. Standard voltage (as supplied) 

 

3 AC 220 - 240  

 

Frequency 

 

Hz 

50 

 

Rated load 

 

kW 

34.8 – 41.1 

 

 

Fuse rating 

 

3 × 100 

 

 

Connection cable, min. cross-section 

 

mm² 

4 × 25 

 

 

Cable screw connector 

 

 

M 50 

 

 

Connection cable (to be ordered separately) 

 

 

 

 

Non-standard voltages:  

 

OS 440 

Standard voltage (as supplied)  

 

3 AC 440  

 

Frequency 

 

Hz 

60 

 

Rated load 

 

kW 

37.9 

 

 

Fuse rating 

 

3 × 63 

 

 

Connection cable, min. cross-section 

 

mm² 

4 × 16 

 

 

Cable screw connector 

 

 

M 40 

 

 

Connection cable (to be ordered separately) 

 

 

 

 

 

Electrical connection must comply with national regulations. 

Connection using multi-pole wall socket in compliance with 
IEC/EN 60309 and IEC/EN 60947 is recommended in order to 
simplify electrical tests. 

If machines are hard-wired, a multi-pole mains switch must be 
provided on site. 

A wall socket or mains isolator must be accessible after 
installation. 

 

 

 

 

Summary of Contents for PT 8803 EL

Page 1: ...02 11 Mat NR 07 803 900 02 Installation plan Tumble dryers Installatieschema Droogautomaat PT 8803 EL PT 8805 EL PT 8807 EL nl NL en GB ...

Page 2: ...eert en in gebruik neemt Dat is veiliger voor uzelf en u voorkomt schade aan uw apparaat Technische wijzigingen voorbehouden It is essential to read the operating and installation instructions before installing commissioning or using the machine This avoids the risk of accidents or damage All rights reserved ...

Page 3: ......

Page 4: ......

Page 5: ......

Page 6: ......

Page 7: ......

Page 8: ......

Page 9: ...e min cross section mm 5 16 Cable screw connector M 50 Connection cable to be ordered separately 2 Standard voltage as supplied V 3 AC 220 240 Frequency Hz 50 Rated load kW 34 8 41 1 Fuse rating A 3 100 Connection cable min cross section mm 4 25 Cable screw connector M 50 Connection cable to be ordered separately Non standard voltages OS 440 Standard voltage as supplied V 3 AC 440 Frequency Hz 60 ...

Page 10: ...As relative humidity inside the vent ducting can be as high as 100 suitable measures must be taken to prevent a backflow of condensate into the machine Air intake Standard connection Air intake from installation site Unobstructed air intake into room recommended corres ponding to 3 times the vent cross section of machine cm 531 A sufficient supply of fresh air should be ensured to replace the air ...

Page 11: ...hine mm 1800 Min wall gap to rear edge of lid mm 500 Net weight kg 286 Dynamic floor load max N 3394 Average heat dissipation dependent on ambient room temperature and programme selected W 973 A Noise level dB A 73 6 A Sound pressure level measured at a distance of 1 m from the machine and at a height of 1 6 m 1 m dB A 62 Installation should only be carried out by authorised fitters in accordance ...

Page 12: ...0 De aansluitkabels worden niet bijgeleverd 2 Standaardspanning af fabriek V 3 AC 220 240 Frequentie Hz 50 Aansluitwaarde kW 34 8 41 1 Zekering A 3 100 Aansluitkabel draaddoorsnede minimaal mm 4 25 Kabelwartel M 50 De aansluitkabels worden niet bijgeleverd Afwijkende spanningen OS 440 Afwijkende spanning af fabriek V 3 AC 440 Frequentie Hz 60 Aansluitwaarde kW 37 9 Zekering A 3 63 Aansluitkabel dr...

Page 13: ...n het apparaat terechtkomt Luchttoevoer Standaardaansluiting Toevoer uit de ruimte waar de machine staat opgesteld Aanbevolen vrije diameter luchttoevoer in de ruimte is 3x de diameter van de luchtafvoer van het apparaat cm 531 Er moet voldoende luchttoevoer zijn naar de ruimte waar het apparaat staat opgesteld om de afgevoerde luchthoeveelheid te compenseren Alternatieve aansluiting Aansluiting l...

Page 14: ... deksel mm 500 Nettogewicht kg 286 Vloerbelasting bij gebruik max N 3 394 Gemiddelde warmteafgifte aan de ruimte afhankelijk van omgevingstemperatuur en gekozen programma W 973 A gewogen geluidsvermogen dB A 73 6 A gewogen geluidsdruk werkplekspecifiek afstand 1 m hoogte 1 6 m dB A 62 De installatiewerkzaamheden mogen alleen door een erkend installateur worden uitgevoerd met inachtneming van alle ...

Reviews: