Installationsplan / Installation plan: PT 8803/8805/8807
Datum / Date: 12.01.2011
Seite / Page: 10
Equipotential
bonding
Connection with male thread
mm
10 × 35
with washers and nut.
M
10
Accessories not included (except with offshore version).
If necessary, equipotential bonding with good galvanic
contact must be provided in accordance with all appropriate
national and local regulations.
Peak load energy
management
Control contact voltage
V
AC 230
Connection cable, min. cross-section
mm²
5 × 1.5
Connection cable (to be ordered separately)
Connection via a flexible supply lead with a separate isolator
is recommended. The isolator should be visible and easily
accessible after machine installation.
Vented
Max. nominal air flow in vented mode (PT 8807 only)
m³/h
1100
Nominal air flow (PT 8803/8805 only)
m³/h
1000
Max. permissible pressure loss
Pa
300
Connection on machine side (ext. diameter)
mm
150
Connection pipe provided on site (int. diameter)
mm
150
Max. temperature
°C
80
As relative humidity inside the vent ducting can be as high as
100%, suitable measures must be taken to prevent a
backflow of condensate into the machine.
Air intake
Standard connection: Air intake from installation site
Unobstructed air intake into room recommended (corres-
ponding to 3 times the vent cross-section of machine)
cm²
531
A sufficient supply of fresh air should be ensured to
replace the air extracted.
Alternative connection: Ducted air intake (from outside
building)
Connector on machine (int. diameter)
mm
161
Connection pipe provided on site (ext. diameter)
mm
160
Lid removal exposes live components! For safety reasons,
the pipe connected for central air intake should be at least
900 mm long and secured using two screws.
Fittings (supplied) Without plinth
2 × clamps
2 × screws DIN 571 (Ø × length)
mm
6 × 40
2 × rawl plugs (Ø × length)
mm
10 × 50
The machine should be bolted to the floor.
Fixing materials for a floating screed floor are to be provided
on site.
On concrete platform
2 × clamps
2 × screws DIN 571 (Ø × length)
mm
6 × 40
2 × rawl plugs (Ø × length)
mm
10 × 50
Machine must be bolted to the floor!
Fixing materials for a floating screed floor are to be provided
on site.