Fittings
(supplied)
Without base:
2 × clamps
2 × screws DIN 571 (Ø × length)
1/4“ x 1 9/16“
6 mm × 40 mm
2 × rawl plugs (Ø × length)
3/8“ x 1 31/32“
10 mm × 50 mm
Machine must be bolted to the floor!
Fixing materials for floor screed have to be provided on
site.
On concrete platform:
2 × clamps
2 × screws DIN 571 (Ø × length)
1/4“ x 1 9/16“
6 mm × 40 mm
2 × rawl plugs (Ø × length)
3/8“ x 1 31/32“
10 mm × 50 mm
Machine must be bolted to the floor!
Fixing materials for floor screed have to be provided on
site.
Machine data
Width
35 21/32“
906 mm
Depth
45 27/32“
1164 mm
Height
55 1/8“
1400 mm
Casing width
35 7/16“
900 mm
Casing depth
41 11/16“
1059 mm
Minimum width of delivery access to installation site
36 7/32“
920 mm
Recommended rear wall gap (measured to front of
machine)
63“
1600 mm
Min. wall gap (to rear edge of lid)
19 11/16“
500 mm
Net weight
476.2 lbs
216 kg
Dynamic floor load, max.
2413 N
Average heat dissipation
(depends on ambient room temperature and selected
program)
2508 BTU/h
735 W
A Noise level
72.8 dB (A)
A Sound pressure level
(measured at a distance of 39 3/8” [1 m] from the
machine and at a height of 63” [1.6 m])
60 dB (A)
Installation should only be carried out by authorized installers in accordance with all local and national regulations.
Follow installation instructions when installing machine! All rights reserved.
Installation plan: PT 8407 D
Date: 16-Oct-2014
Page: 13
Summary of Contents for PT 8407 D
Page 1: ...Installation Plan Tumble dryer PT 8407 D Steam Heated en US 23 15 M Nr 10 002 520 ...
Page 4: ... 45 7 8 41 11 16 63 2 5 7 8 6 1 4 6 3 8 PT 8407 D measurements in inches 4 ...
Page 7: ...PT 8407 D measurements in millimeters 7 ...
Page 8: ... PT 8407 D measurements in millimeters 8 ...