background image

 

Technical datasheet: PT 7188 EL 

Date: 28.03.2014 

 

Page: 8 

 

 

 

 

Vented

 

Nominal air throughput in vented mode

 

Max. permissible pressure loss 
Waste air/gas temperature, max. 
Connector on machine (int. diameter) 
Connection pipe provided on site (ext. diameter) 
 
Miele adapter, Mat. No. 6595070 (int. diameter 100 mm) for 
flexible aluminium ducting and adapter, Mat. No. 915051, 
(ext. diameter 110 mm) for connection to standard heat-
resistant plastic pipes supplied. 
As relative humidity inside the vent ducting can be as high as 
100%, suitable measures must be taken to prevent a back-
flow of condensate into the machine.

 

m³/h

 

Pa 
°C 
mm 
mm

 

320

 

420 
80 
100 
100

 

 

 

 

Air intake 

 

Standard Connection: 

 

Air intake from installation site 
Min. air intake cross-section

 

(to prevent draughts in room) 

 A sufficient supply of fresh air should be ensured to replace 
the air extracted. 

 
cm² 

 
237 

 

 

 

Fittings (supplied)  Miele US 6008 plinth 

 

 

4 × metal angled brackets 

 

(to secure machine to plinth) 

 

 

4 × screws DIN 571 (Ø × length) 

mm 

6 × 50 

 

 

4 × rawl plugs (Ø × length) 

mm 

8 × 40 

 

 

Machine must be bolted to the floor! 
Fixing materials for a floating screed floor are to be provided 
on site. 

 

 

 

 

On concrete platform 

 

 

 

 

2 × clamps 

 

 

 

 

2 × screws DIN 571 (Ø × length) 

mm 

6 × 50 

 

 

2 × rawl plugs (Ø × length) 

mm 

8 × 40 

 

 

Machine must be bolted to the floor! 

 

 

 

 

Fixing materials for a floating screed floor are to be provided 
on site. 

 

 
 

 

Machine data 

Unit width 

mm 

700 

 

 

Machine depth 

mm 

763 

 

 

Unit height 

mm 

1020 

 

 

Casing width 

mm 

692 

 

 

Casing depth 

mm 

690 

 

 

Minimum width of delivery access to installation site 

mm 

720 

 

 

Minimum rear wall gap (measured to front of machine) 

mm 

1100 

 

 

Wall gap (to front of machine)

 

Minimum gap ensures sufficient space for maintenance and 
servicing. 

mm 

900 

 

 

Net weight 

kg 

77 

 

 

Dynamic floor load, max. 

1000 

 

 

Average heat dissipation

 

(dependent on ambient room temperature and programme 
selected) 

450 

 

 

Sound pressure (re 20 mPA),

 

workplace-related (at distance of 1 m and height of 1.6 m) 

dB (A) 

<70 

Installation should only be carried out by authorized fitters in accordance with valid regulations! 
Observe installation instructions when installing machine! All rights reserved! Measurements in mm. 

  