Technical datasheet: PT 7188 EL
Date: 28.03.2014
Page: 8
Vented
Nominal air throughput in vented mode
Max. permissible pressure loss
Waste air/gas temperature, max.
Connector on machine (int. diameter)
Connection pipe provided on site (ext. diameter)
Miele adapter, Mat. No. 6595070 (int. diameter 100 mm) for
flexible aluminium ducting and adapter, Mat. No. 915051,
(ext. diameter 110 mm) for connection to standard heat-
resistant plastic pipes supplied.
As relative humidity inside the vent ducting can be as high as
100%, suitable measures must be taken to prevent a back-
flow of condensate into the machine.
m³/h
Pa
°C
mm
mm
320
420
80
100
100
Air intake
Standard Connection:
Air intake from installation site
Min. air intake cross-section
(to prevent draughts in room)
A sufficient supply of fresh air should be ensured to replace
the air extracted.
cm²
237
Fittings (supplied) Miele US 6008 plinth
4 × metal angled brackets
(to secure machine to plinth)
4 × screws DIN 571 (Ø × length)
mm
6 × 50
4 × rawl plugs (Ø × length)
mm
8 × 40
Machine must be bolted to the floor!
Fixing materials for a floating screed floor are to be provided
on site.
On concrete platform
2 × clamps
2 × screws DIN 571 (Ø × length)
mm
6 × 50
2 × rawl plugs (Ø × length)
mm
8 × 40
Machine must be bolted to the floor!
Fixing materials for a floating screed floor are to be provided
on site.
Machine data
Unit width
mm
700
Machine depth
mm
763
Unit height
mm
1020
Casing width
mm
692
Casing depth
mm
690
Minimum width of delivery access to installation site
mm
720
Minimum rear wall gap (measured to front of machine)
mm
1100
Wall gap (to front of machine)
Minimum gap ensures sufficient space for maintenance and
servicing.
mm
900
Net weight
kg
77
Dynamic floor load, max.
N
1000
Average heat dissipation
(dependent on ambient room temperature and programme
selected)
W
450
Sound pressure (re 20 mPA),
workplace-related (at distance of 1 m and height of 1.6 m)
dB (A)
<70
Installation should only be carried out by authorized fitters in accordance with valid regulations!
Observe installation instructions when installing machine! All rights reserved! Measurements in mm.
Summary of Contents for PT 7188 EL
Page 1: ...14 14 M Nr 09 923 550 Installation Plan Tumble dryer PT 7188 EL en AU ...
Page 3: ......
Page 4: ......
Page 5: ......
Page 6: ......