Technical datasheet: PT 7188 EL
Date: 28.03.2014
Page: 7
Technical datasheet
Tumble dryer:
Heating:
PT 7188
Electric (EL)
Legend:
Abbreviations in bold type:
Connection required
en - AU
Abbreviations in circle with dashes:
Connection optional or required depending on model version
Optional extras:
UM
Miele plinth
US 6008 (US = plinth with drawer)
Height
mm
320
Width
mm
692
Depth
mm
685
BS
Concrete plinth
Quality and density of concrete must comply with load. Con-
crete plinth must be firmly secured to floor!
Recommended height
mm
300
Minimum height
mm
70
Recommended width
mm
≥700
Recommended depth
mm
≥700
Machine connections:
Electrical
connection
1. Standard voltage (as supplied)
V
1N AC 230 - 240
Frequency
Hz
50
Rated load
kW
5.78
–
6.24
Fuse rating
A
1 × 25
Supply lead cross-section
mm²
3 × 2.5
Length of supply lead
mm
2170
Supply lead with plug (supplied)
Electrical connection must comply with national regulations.
A wall socket or mains isolator must be easy accessible after
installation.
Reinstallation of the supply point, changes to the equipment
or checks on the protective conductor, including determination
of correct fuse rating, should only be performed by a properly
trained electrician.