background image

 

Technical datasheet: PT 7188 EL 

Date: 28.03.2014 

 

Page: 7 

 

 

 
 

Technical datasheet 

 

 
 

 

 

 

 

 

Tumble dryer: 
Heating: 
 

PT 7188 
Electric (EL) 

 
 
 

 

Legend: 

 

Abbreviations in bold type:

 

Connection required 

en - AU 

 

 

 

Abbreviations in circle with dashes:

 

Connection optional or required depending on model version 

 

 

 

 

 

Optional extras: 

 

UM 

Miele plinth 

US 6008 (US = plinth with drawer) 

 

 

Height 

mm 

320 

 

Width 

mm 

692 

 

 

Depth 

mm 

685 

 
BS

 

Concrete plinth 

Quality and density of concrete must comply with load. Con-
crete plinth must be firmly secured to floor! 

 

 

 

 

Recommended height 

mm 

300 

 

 

Minimum height 

mm 

70 

 

 

Recommended width 

mm 

≥700

 

 

 

Recommended depth 

mm 

≥700

 

 

Machine connections: 

 

 

Electrical  

connection 

1. Standard voltage (as supplied)  

1N AC 230 - 240  

Frequency 

Hz 

50 

 

Rated load 

kW 

5.78 

 6.24 

 

Fuse rating 

1 × 25 

 

 

Supply lead cross-section 

mm² 

3 × 2.5 

 

 

Length of supply lead 

mm  

2170 

 

 

Supply lead with plug (supplied) 

 

 

 

 

Electrical connection must comply with national regulations.  
A wall socket or mains isolator must be easy accessible after 
installation. 
Reinstallation of the supply point, changes to the equipment 
or checks on the protective conductor, including determination 
of correct fuse rating, should only be performed by a properly 
trained electrician. 

 

 

 
 

 

Reviews: