Technisches Datenblatt / Technical datasheet: PT 7186 EL
Datum / Date: 28.10.2009
Seite / Page: 9
Non-standard voltages:
OS 440
1. Standard voltage (as supplied)
V
3 AC 440
Frequency
Hz
60
Rated load
kW
8.5
Fuse rating
A
3 × 16
Connection cable cross-sectional area
mm²
4 × 1.5
Connection cable length
mm
2000
Connection cable without plug
(supplied as standard)
Electrical connection must be in accordance with local and
national regulations.
Plug and socket connection in accordance with IEC/EN
60309 and IEC/EN 60947 recommended to facilitate
electrical safety tests.
If the machine is connected via a fixed connection, a multi-
pole switch must be provided on site to ensure complete
isolation. Switches with a contact opening of more than 3 mm
should be used. Such switches are, e.g., LS switches, fuses
and contactors (IEC/EN 60947).
A wall socket or mains isolator must be visible and accessible
after installation.
A new connection, modification of an existing installation or
earth checking, including the determination of suitable fuse
rating, may only be carried out by a suitably qualified
electrician in accordance with all local and national
regulations.
Vented
Nominal air throughput in vented mode
m³/h
320
Max. pressure loss
Pa
420
Max. exhaust air/gas temperature
°C
80
Connection sleeve on machine (inner diameter)
mm
100
Connection diameter on site (outer diameter)
mm
100
Connection adapter Miele Mat. no. 6595070 (inner diameter
100 mm) for flexible aluminium duct and adapter piece Miele
Mat. no. 915051 (outer diameter 110 mm) for connection to
normal heat-resistant plastic ducting are supplied as
standard.
As relative humidity in ducting can be as high as 100%,
suitable measures must be taken to prevent a backflow of
condensate into the machine.
Air intake
Standard connection:
Air intake from installation site
Recommended air intake vent cross-sectional area
(to prevent draughts in installation site)
cm²
237
Sufficient air intake should be available to replace displaced
volume of air.