Technisches Datenblatt / Technical datasheet: PT 7186 EL 
Datum / Date: 28.10.2009 

  Seite / Page: 9 

 

 

 

Non-standard voltages:

 

 

OS 440 

1. Standard voltage (as supplied)

 

 

V

 

3 AC 440

 

 

Frequency

 

 

Hz

 

60 

 

Rated load

 

 

kW

 

8.5

 

 

 

Fuse rating

 

 

A

 

3 × 16

 

 

 

Connection cable cross-sectional area 

 

mm² 

4 × 1.5 

 

 

Connection cable length 

 

mm 

2000 

 

 

Connection cable without plug 
(supplied as standard) 

 

 

 

 

 

Electrical connection must be in accordance with local and 
national regulations. 

Plug and socket connection in accordance with IEC/EN 
60309 and IEC/EN 60947 recommended to facilitate 
electrical safety tests. 
If the machine is connected via a fixed connection, a multi-
pole switch must be provided on site to ensure complete 
isolation. Switches with a contact opening of more than 3 mm 
should be used. Such switches are, e.g., LS switches, fuses 
and contactors (IEC/EN 60947). 
A wall socket or mains isolator must be visible and accessible 
after installation. 

A new connection, modification of an existing installation or 
earth checking, including the determination of suitable fuse 
rating, may only be carried out by a suitably qualified 
electrician in accordance with all local and national 
regulations. 

 

 

 

Vented 

Nominal air throughput in vented mode 

m³/h 

320 

Max. pressure loss 

Pa 

420 

 

Max. exhaust air/gas temperature 

°C 

80 

 

Connection sleeve on machine (inner diameter) 

mm 

100 

 

 

Connection diameter on site (outer diameter) 

mm 

100 

 

 

Connection adapter Miele Mat. no. 6595070 (inner diameter 
100 mm) for flexible aluminium duct and adapter piece Miele 
Mat. no. 915051 (outer diameter 110 mm) for connection to 
normal heat-resistant plastic ducting are supplied as 
standard. 

 

 

 

 

As relative humidity in ducting can be as high as 100%, 
suitable measures must be taken to prevent a backflow of 
condensate into the machine. 

 

 

 

Air intake 

Standard connection: 

 

 

Air intake from installation site 

 

 

 

Recommended air intake vent cross-sectional area 
(to prevent draughts in installation site) 

cm² 

237 

 

Sufficient air intake should be available to replace displaced 
volume of air. 

 

 

 

Summary of Contents for PT 7186 EL

Page 1: ...11 09 Mat No 07 738 250 01 Installation recommendations Tumble dryers PT 7186 EL en GB ...

Page 2: ... No 07 738 250 01 2 It is essential to read the operating and installation instructions before installing commissioning or using the machine This avoids the risk of accidents or damage All rights reserved ...

Page 3: ......

Page 4: ......

Page 5: ......

Page 6: ......

Page 7: ......

Page 8: ...h mm 700 Recommended depth mm 700 It must be ensured that the concrete plinth is anchored to the floor Machine connections Electrical connection 1 Standard voltage as supplied V 3N AC 400 Frequency Hz 50 Rated load kW 8 5 Fuse rating A 3 16 Connection cable cross sectional area mm 5 1 5 Connection cable length mm 2170 Connection cable without plug supplied as standard Country variations 1 Standard...

Page 9: ...nstallation A new connection modification of an existing installation or earth checking including the determination of suitable fuse rating may only be carried out by a suitably qualified electrician in accordance with all local and national regulations Vented Nominal air throughput in vented mode m h 320 Max pressure loss Pa 420 Max exhaust air gas temperature C 80 Connection sleeve on machine in...

Page 10: ...for floating screed floor to be provided on site Machine data Machine width mm 700 Machine depth mm 763 Machine height mm 1020 Casing width mm 692 Casing depth mm 690 Min access width to installation site mm 720 Minimum rear wall gap measured to front of machine mm 1100 Minimum wall gap to front edge of machine With an installation with the minimum gap additional work may be required when service ...

Reviews: