Miele PT 7186 EL Installation Manual Download Page 10

 

Technisches Datenblatt / Technical datasheet: PT 7186 EL 
Datum / Date: 28.10.2009 

Seite / Page: 10 

 

 

 

Fittings 

(supplied) 

Miele plinth UG/UO 6008 

 

 

4 × fasteners (to secure machine to plinth) 

 

 

4 × screws DIN 571 (Ø × length) 

mm 

8 × 65 

 

4 × rawl plugs (Ø × length) 

mm 

12 × 60 

 

 

Machine must be bolted to the floor! 

 

 

 

 

Fixing materials for floating screed floor to be provided on site   

 

 

 

Miele plinth US 6008 

 

 

 

 

4 × fasteners (to secure machine to plinth) 

 

 

 

 

4 × screws DIN 571 (Ø × length) 

mm 

6 × 50 

 

 

4 × rawl plugs (Ø × length) 

mm 

8 × 40 

 

 

Machine must be bolted to the floor! 

 

 

 

 

Fixing materials for floating screed floor to be provided on site   

 

 

 

On concrete plinth 

 

 

 

 

2 × metal brackets 

mm 

6 × 50 

 

 

2 × screws DIN 571 (Ø × length) 

mm 

8 × 40 

 

 

2 × rawl plugs (Ø × length) 

 

 

 

 

Machine must be bolted to the floor! 

 

 

 

 

Fixing materials for floating screed floor to be provided on site   

 

 

Machine data 

Machine width 

mm 

700 

 

Machine depth 

mm 

763 

 

 

Machine height 

mm 

1020 

 

 

Casing width 

mm 

692 

 

 

Casing depth 

mm 

690 

 

 

Min. access width to installation site 

mm 

720 

 

 

Minimum rear wall gap (measured to front of machine) 

mm 

1100 

 

 

Minimum wall gap (to front edge of machine) 
With an installation with the minimum gap, additional work 
may be required when service or repair work is necessary. 

mm 

900 

 

 

Net weight 

kg 

77 

 

 

Dynamic floor load, max. 

1000 

 

 

Static floor load, max. 

Not yet available

 

 

 

Average heat dissipation 
(dependent on ambient room temperature and programme 
selected) 

450 

 

 

Sound pressure level (re 20 mPa), 
(measured at a distance of 1 m from the machine and at a 
height of 1.6 m) 

dB (A) 

<70 

Installation should only be carried out by authorised fitters in accordance with valid regulations!  
Observe installation instructions when installing machine! All rights reserved! Dimensions in mm 

 

Summary of Contents for PT 7186 EL

Page 1: ...11 09 Mat No 07 738 250 01 Installation recommendations Tumble dryers PT 7186 EL en GB ...

Page 2: ... No 07 738 250 01 2 It is essential to read the operating and installation instructions before installing commissioning or using the machine This avoids the risk of accidents or damage All rights reserved ...

Page 3: ......

Page 4: ......

Page 5: ......

Page 6: ......

Page 7: ......

Page 8: ...h mm 700 Recommended depth mm 700 It must be ensured that the concrete plinth is anchored to the floor Machine connections Electrical connection 1 Standard voltage as supplied V 3N AC 400 Frequency Hz 50 Rated load kW 8 5 Fuse rating A 3 16 Connection cable cross sectional area mm 5 1 5 Connection cable length mm 2170 Connection cable without plug supplied as standard Country variations 1 Standard...

Page 9: ...nstallation A new connection modification of an existing installation or earth checking including the determination of suitable fuse rating may only be carried out by a suitably qualified electrician in accordance with all local and national regulations Vented Nominal air throughput in vented mode m h 320 Max pressure loss Pa 420 Max exhaust air gas temperature C 80 Connection sleeve on machine in...

Page 10: ...for floating screed floor to be provided on site Machine data Machine width mm 700 Machine depth mm 763 Machine height mm 1020 Casing width mm 692 Casing depth mm 690 Min access width to installation site mm 720 Minimum rear wall gap measured to front of machine mm 1100 Minimum wall gap to front edge of machine With an installation with the minimum gap additional work may be required when service ...

Reviews: