Supervisor level
48
This option must always be selected if there is no exhaust air flap to activate. This pre-
vents the programme from being cancelled.
- On
- 0 seconds
- 1 second
- 2 seconds
...
- 300 seconds
Additional fan
External hardware is connected via the Miele XCI box.
If an extra fan is connected, it must be switched on at the same time as the drive unit.
- Off
- On
Pressure sensor
External hardware is connected via the Miele XCI box.
When using a shared exhaust air duct, one tumble dryer may have to be switched off or
suppressed from the outset if certain pressure levels have built up in the ducting. Be-
cause the pressure sensor is an external unit, there is the option of reading in both a lo-
gical normally open contact or a normally closed contact.
A message appears in the display while the exhaust air flap is open.
- Off = Not active
-
NO contact
= Active
Responds to
high potential
-
NC contact
= Active
Responds to
low potential
Peak load signal
External hardware is connected via the Miele XCI box.
The peak-load negotiation function enables the tumble dryer to be connected to an en-
ergy management system. When a signal is registered, the tumble dryer's heater is
switched off for a short period or the appliance is prevented from being switched on.
The tumble dryer may only be operated with a peak-load system if this system is connec-
ted to the tumble dryer via the Miele XCI box.
- Factory default: no function
- Peak load with 230 V
- Peak load with 0 V