en - Using the machine
45
Control panel
1
2
3
4
5
6
Control panel behind the lockable access flap
a
button
b
button
c
button
d
Green LED
Flashes when starting/ready for use, lights up during operation.
e
Yellow LED
CO
2
Flashes in the event of a CO
2
warning, lights up when heating is
active.
f
Red LED
Flashes in the event of a fault.
Overview of oper-
ating modes
Manual mode
During operation, the fan speed can be changed individually between 20–100 %
in 5 % increments via the
and
buttons.
Optional initial flow can be switched on before normal operation.
time
mode
Same as
Manual mode
but with additional clock function (timer) which can be
used to set a switch-on time and switch-off time for each day.
CO2 mode
The fan speed is automatically regulated according to the set room size. The need
for ventilation is indicated via an LED and a display message.
Optional initial flow can be switched on before normal operation and a circulation
function can be activated.
CO2+time mode
Same as
CO2 mode
but with additional clock function (timer) which can be used
to set a switch-on time and switch-off time for each day.
Overview of oper-
ating statuses
The following operating statuses are shown in the display:
Ready for opera-
tion
The power supply has been connected and the appliance is ready for operation.
Flow
The fan runs at a set flow rate and duration to clean the air before the air purifier
switches to normal operation.
Manual opera-
tion
time
operation
CO2 operation
CO2+time oper-
ation
The appliance is in normal operation.
ThermoControl
active
Relevant pathogens are deactivated automatically by Miele ThermoControl after
every use.
Fan run-on
The fan keeps running after Miele ThermoControl in order to cool the filter.
Intensive circ.
active
The fan runs at a higher speed for a short period in order to quickly circulate the
air within the room.