Once the flow of water ceases:
^
Pull the drain filter entirely out.
^
Thoroughly clean the filter.
^
Turn the pump blade by hand to
check that it moves freely, and
remove any foreign objects (buttons,
coins, etc.) that are causing an
obstruction.
^
Put the drain filter back in place and
tighten it down.
,
If the drain filter is not securely
tightened, there is a risk of water
leakage during operation.
Opening the loading door
,
NEVER reach into the drum until
is has completely stopped moving.
Reaching into a moving drum
carries the risk of serious injury.
^
Pull the emergency release (see
illustration). The loading door will
open.
Troubleshooting
40