The appliance can be installed in a
kitchen run. To match the height of the
rest of the kitchen, the appliance can
be fitted with a suitable top box
a
.
A ventilation gap of at least 50 mm
depth must be allowed for behind the
appliance for air to circulate.
The cross section of the air outlet under
the room ceiling must be at least 300
cm
2
to ensure that air can circulate
without hindrance. Otherwise the
appliance has to work too hard
resulting in an increase in electricity
consumption. The larger the cross
section, the more efficient the
appliance.
The air inlet and outlet must not be
covered or blocked in any way.
They should be dusted on a regular
basis.
When
installed next to a wall
c
a
distance of approx. 40 mm is needed
on the hinge side between the wall and
the appliance
b
, so that the doors and
the handles have sufficient space for
opening.
When
securing to adjoining furniture
d
or if a spacer is fitted between the
appliance and the wall, please note
the following:
^
Ensure that the door has sufficient
space for opening fully after the
appliance has been secured.
^
To secure the appliance
b
to
adjoining kitchen furniture
d
use
self-tapping screws. The
depth
of the
screw must not exceed
10 mm
. See
small illustration.
Building in the appliance